My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2004 Septic system
Orono
>
Property Files
>
Street Address
>
W
>
Woodhaven Drive
>
2550 Woodhaven Drive - 33-118-23-41-0007
>
Septic
>
2004 Septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:51:13 PM
Creation date
2/24/2020 12:45:20 PM
Metadata
Fields
Template:
x Address Old
House Number
2550
Street Name
Woodhaven
Street Type
Drive
Address
2550 Woodhaven Drive
Document Type
Septic
PIN
3311823410007
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PUMP SELECTION PROCEDURE <br /> Perforation Discharges in gpm <br /> A. Determine pump capacity: perforation diameter <br /> gravity distribution head (inches) <br /> Minimum required discharge is 10 gpm (feet) 1/8* 3/16 7/32 1/4 <br /> 2.Maximum suggested discharge is 45 gpm 1.Oa 0.18 0.42 0.56 0.74 <br /> pressure distribution 2.Ob 0.26 0.59 0.80 1.04 <br /> see pressure design worksheeet 5.0 0.41 0.94 1.26 1.65 <br /> Selected pump capacity: Lo 2- gpm a Use 1.0 foot for single-family homes. <br /> b Use 2.0 feet for anything else. <br /> " Potential for plugging <br /> B. Determine head requirements: <br /> 1.Elevation difference between pump and point of discharge. <br /> 10 feet <br /> 2. Special head requirement: <br /> If pumping to a pressure distribution system,five feet for pressure <br /> required at manifold.If gravity system,zero. 5 feet <br /> soil treatment <br /> 3. Friction loss - system ;49191.¢4. of <br /> a. Enter friction loss table with gpm and pipe diameter. iengtsipe <br /> Read friction loss in feet per 100 feet from table. Inlet ' oNa,r,,..,.. e elevation <br /> difference <br /> F.L. = ,0 ft./100 ft of pipe pipe <br /> b. Determine total pipe length from pump to discharger4, y' C6 2 <br /> point. Estimate by adding 25 percent to pipe length for fitting <br /> loss. Equivalent pipe length times 1.25 =total pipe length <br /> (o D x 1.25 = 7 J feet <br /> c. Calculate total friction loss by multiplying friction loss Friction Loss in Plastic Pipe <br /> in ft/100 ft by equivalent pipe length. Per 100 feet <br /> Total friction loss= a ). 0 x '?st.- =100= I to feetnominal <br /> pipe diameter <br /> 4.Total head required is the sum of elevation difference,special head flowrate1.5" 2" 3" <br /> requirements,and total friction loss. 20 2.47 0.73 0.11 <br /> v + + Co/ (1) (2) (3c) .? 4 1 11 0:16. <br /> Total head: 3 ) feet 30 5.23 1.55 0.23 <br /> 35 6.96 2.06 0.30 <br /> iajnM 2.64 0.39 <br /> 45 11.07 3.28 0.48 <br /> C. Pump selection 50 13.46 3.99 0.58 <br /> Y.'Z4.76' . 0.70 <br /> 1. A pump must be selected to deliver at least (oZgpm 60 zO.0 5.60 0.82 <br /> (Step A)with at least 3) feet of total head (Step B). 65 6.48 0.95 <br /> 70 7.44 1.09 <br />
The URL can be used to link to this page
Your browser does not support the video tag.