Rhvac-Residential&Light Commercial HVAC Loads is Elite Software Development,Inc. <br /> Sabre Plumbing&Heating 7800-Barlow <br /> Plymouth.MN 55447 Page 4 <br /> Total Building Summary Loads <br /> .. <br /> Low EE: Glazing-LowEE Builder Grade .31 U-value, .29 454.8 12,262 0 11,417 11,417 <br /> SHGC, Window and Patio Door, u-value 0.31, SHGC <br /> 0.29 <br /> 11J: Door-Metal - Fiberglass Core 41.8 2,181 0 602 602 <br /> 15A-15sffc-8:Wall-Basement, concrete block wall, R-15 1548 4,890 0 89 89 <br /> foam board to floor, no framing, no interior finish, <br /> filled core, 8'floor depth <br /> 12F-Osw: Wall-Frame, R-21 insulation in 2 x 6 stud 2363.8 13,367 0 2,044 2,044 <br /> cavity, no board insulation, siding finish, wood studs <br /> RJ 20 Spray Foam: Wall-Frame, Custom, Rim Joist R-20 347.5 1,512 0 424 424 <br /> Closed Cell Spray Foam <br /> R49 16B-49: Roof/Ceiling-Under Attic with Insulation on 2464 4,930 0 2,720 2,720 <br /> Attic Floor(also use for Knee Walls and Partition <br /> Ceilings), Custom, R-49 Blown Insulation, No <br /> Radiant Barrier, Vented Attic, Asphalt Shingles <br /> 21A-20: Floor-Basement, Concrete slab, any thickness, 2 2448 5,750 0 0 0 <br /> or more feet below grade, no insulation below floor, <br /> any floor cover, shortest side of floor slab is 20'wide <br /> Subtotals for structure: 44,892 0 17,296 17,296 <br /> People: 6 1,200 1,380 2,580 <br /> Equipment: 901 3,638 4,539 <br /> Lighting: 750 2,558 2,558 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0 <br /> Ventilation: Winter CFM: 175, Summer CFM: 175 6,500 4,061 971 5,032 <br /> Humidification (Winter) 15.67 gal/day : 5,745 0 0 0 <br /> AED Excursion: 0 0 2,099 2,099 <br /> Total Building Load Totals: 57,137 6,162 27,942 34,104 <br /> a ; n <br /> :1',-: <br /> d . �cx#r,u ���x 3 .. . . . . ..."xi§� ti��a�= s.,.,144i:1-'4:0L--:,;4 7 ,:a;: <br /> Total Building Supply CFM: 1,264 CFM Per Square ft.: 0.257 <br /> Square ft. of Room Area: 4,912 Square ft. Per Ton: 1,728 <br /> Volume (ft3)of Cond. Space: 46,672 <br /> :, a s .a ,w e,y':fiva.`t3e ial5:11 1,a`' n `.. , .. , ,.,,4 ., a dh'a10 ,rf°+ „y '1 <br /> Total Heating Required Including Ventilation Air: 57,137 Btuh 57.137 MBH <br /> Total Sensible Gain: 27,942 Btuh 82 % <br /> Total Latent Gain: 6,162 Btuh 18 % <br /> Total Cooling Required Including Ventilation Air: 34,104 Btuh 2.84 Tons(Based On Sensible + Latent) <br /> + ,: x ,- . . : , w,„,, ., , ,k.',..,,,,,,,,:- 1 <br /> Rhvac is an ACCA approved Manual J and Manual D computer program. <br /> Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at <br /> your design conditions. <br /> Monday, May 16, 2016, 10:05 AM <br />