10-08-2014 - compliance inspection for septic system
Orono
>
Property Files
>
Street Address
>
W
>
Wolverton Place
>
4550 Wolverton Pl - 31-118-23-31-0013
>
Septic
>
10-08-2014 - compliance inspection for septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:30:44 PM
Creation date
2/21/2020 8:31:43 AM
Metadata
Fields
Template:
x Address Old
House Number
4550
Street Name
Wolverton
Street Type
Place
Address
4550 Wolverton Place
Document Type
Septic
PIN
3111823310013
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2011 purple code Mound Design <br /> www.SepticResource.com (vers 12.6) <br /> Property Owner: Natural Environmental Corporation Date: 10/8/2014 <br /> Site Address: 4550 Wolverton Place,Orono PID: <br /> Comments: <br /> instructions: =site specific input *adjust if desired =self-calculated(DO NOT ADJUST) <br /> U 5 bedroom Type I Residential System <br /> 2) 750 GPD design flow <br /> 3) [ No Garbage disposal or pumped to septic existing 3-1000 gallon tanks <br /> 4) 3000 Gal Septic tank(code minimum) 3000 Gal Septic tank(design size/LUG req'd) <br /> Tank options: none <br /> 5) 1.2 GPD/ft2 mound sand loading rate <br /> 6) 10 ft rockbed width 62.5 ft rockbed length &rtW--^^ tet,- -"go"3- <br /> 7) 3.0 ft lateral spacing 3.0 ft perforation spacing (maximum of 3 for both) <br /> end feed manifold connection <br /> 5) 3 laterals 60.5 feet long ( 21.0 ,perfs/lateral 63 perfs total <br /> (1/2 a perf means the first perf starts at the middle feed manifold) <br /> 9) 1/4" inch perfs at 1 feet residual head gives 0.74 gpm flow rate per perforation <br /> for this perf size&spacing,&pipe size on line 12,max perfs/lateral= n,line#8 must be less--> OK <br /> lo) 4.0 doses per day (4 minimum) <br /> l i) 188 gallons per dose (treatment volume) <br /> 12) 2.00 inch diameter laterals(or smaller)will meet"5x pipe volume" <br /> 2.00 inch diameter laterals(or smaller)must be used to meet"4x pipe volume"requirement <br /> 2.00 inch diameter laterals(or smaller)will meet"3x pipe volume" <br /> 13) 25 feet of 2.0 inch supply tine leads to 4 gallons of drainback volume <br /> (Tip:"top feed"manifold to control the drainback) <br /> 14) 192 gallons TOTAL pump out volume(treatment+drainback) <br /> 15) 7 feet vertical tiff t from pump to dispersal area,leads to a: <br /> )6) 47 GPM® 14 feet of head, Pump requirement (note:>50gpm may require an extra 3-6'of head) <br /> 17) 1250 gal Dose tank(code minimum) 1250 gal Dose tank(design size/LUG req'd) at 13.00 gpi <br /> leads to a <br /> 18) 14.8 inch swing on Demand float, or timed dosing of 4.1 min ON (confirm pump rate with drawdown <br /> (to deliver Average flow, 66%of Peak design flow) 9 hrs OFF test and adjust as necessary) <br /> )9) 12 inches from bottom of tank to"Pump OFF'float <br /> 20) 27 inches from bottom of tank to"Pump ON"float,or 12 inches to"Timer ON"float if time dosed <br /> 21) 30 inches from bottom of tank to"Hi Level"float,or 40 inches to"Hi Levet"float if time dosed <br /> 22) 860 gallons reserve capacity (after High Level Alarm is activated) <br /> II <br />