Laserfiche WebLink
Job Truss Truss Type Oty Ply <br /> 001 Fl FLOOR 1 1 <br /> Job Reference(optional) <br /> P&M Truss Inc.,Isanti,MN 55040 7.220 s Dec 29 2009 MiTek Industries,Inc. Wed Feb 01 12:37:38 2012 Page 1 <br /> I 0712 1 1 237 1 1 202 ( I 0-11-10 I l 0-7-12 <br /> Seale.1172 <br /> 3W= <br /> 1 IA II 2 3.= 3 334= 4 10 II 5 334= 6 14411 7 0 3v6= 9 1M II <br /> \\,1 H <br /> '..--''''..'...'.....'''' ..................:01 E. <br /> W1 W 3 Wt W <br /> o. <br /> o e e ®®® <br /> 1 W 11 36= 335= 334= 134 11 <br /> 17 16 15 14 13 12 11 10 <br /> 3.= <br /> 334= 334= <br /> I 14-5-0 I <br /> 14-5-0 <br /> Plate Offsets(X,Y):)3:0-1-8,Edge),(7:0-1-8,Edge),[120-1-8,Edge),115:0-1-8,Edge) <br /> LOADING(psf) SPACING 1-4-0 CSI DEFL in (loc) I/dell L/d PLATES GRIP <br /> TCLL 40.0 Plates Increase 1.00 TC 0.18 Vert(LL) -0.06 13-14 >999 360 MT20 197/144 <br /> TCDL 15.0 Lumber Increase 1.00 BC 0.43 Vert(TL) -0.13 13-14 >999 240 <br /> BCLL 0.0 Rep Stress!nor YES WB 0.23 Horz(TL) 0.02 10 n/a Na <br /> BCDL 5.0 Code MNSRC/TPI2002 (Matrix) Weight:64 lb <br /> LUMBER BRACING <br /> TOP CHORD 4 X 2 SPF No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. <br /> BOT CHORD 4 X 2 SPF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br /> WEBS 4 X 2 SPF No.2 <br /> REACTIONS (lb/size) 17=572/Mechanical, 10=572/Mechanical <br /> FORCES (lb)-Maximum Compression/Mwdmum Tension <br /> TOP CHORD 1-17=0/11,9-10=0/15,1-2=0/0,2-3=-1049/0,3-4-1411/0,4-5=-1411/0,5-6—1265/0,6-7=-1265/0,7-8=-1042/0,8-9=0/0 <br /> BOT CHORD 16-17=0/328,15-16=0/328,14-15=0/1049,13-14=0/1495,12-13=0/1042,11-12=0/331,10-11=0/331 <br /> WEBS 2-17=-671/0,2-16=0/18,8-10=-676/0,8-11=0/19,8-12=0/819,7-12=-407/0,2-15=0/830,3-15=-402/0,3-14=0/431,4-14=-158/0,5-14=-97/0,5-13=-266/0,6-13=-117/0,7-13=0/359 <br /> NOTES (3) <br /> 1)Refer to girder(s)for truss to truss connections. <br /> 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <br /> 3)This truss is designed in accordance with the Minnesota State Residential Building Code.No increased unbalanced loads or drift loads have been considered.The building designer should verify the adequacy of the design loads as <br /> the component is incorporated into the overall structure. <br /> LOAD CASE(S) Standard <br /> • <br /> .5��Jo4-14er - — Q <br /> P ac ia.-oac , V <br />