My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 - 00047 - in-ground pool
Orono
>
Property Files
>
Street Address
>
W
>
Windjammer Lane
>
870 Windjammer Lane - 07-117-23-11-0012
>
Permits/Inspections
>
2017 - 00047 - in-ground pool
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:29:39 PM
Creation date
2/20/2020 11:01:58 AM
Metadata
Fields
Template:
x Address Old
House Number
870
Street Name
Windjammer
Street Type
Lane
Address
870 Windjammer La
Document Type
Permits/Inspections
PIN
0711723110012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JCT"-C I—CCJC)'i £'4•`).D P.CJCJ YJG <br /> PERIMETER DEFLECTION TEST <br /> The perimeter deflection test was conducted on both Cover-Pool safety covers in <br /> accordance with section 9.2 of ASTM ES 13. With a 50 lb. weight placed 4' from the <br /> edge of the pool on top of the safety cover, the test object was unable to pass through <br /> any opening at the perimeter of the pool. Both Cover-Pool safety covers met the <br /> performance requirements for the perimeter deflection test as outlined in ASTM ES 13 <br /> section 7.2. <br /> SURFACE DRAINAGE TEST <br /> On June 12, 1990, the surface drainage test was conducted on a Cover-Pool safety <br /> cover which was installed on a local private pool. The tracking system was an under <br /> track system. The pool dimensions were 14.17'x42.5'. The surface drainage test was <br /> conducted in accordance with ASTM ES 13 section 9.3. Water was applied evenly at <br /> a rate of 11.7 gpm per 1000 sq. ft. A small sump pump, with discharge capacity of 20 <br /> gpm, was placed at one end of the safety cover with the discharge hose snaking the <br /> length of the pool, on top of the safety cover, and discharging at the opposite end from <br /> the pump. The water was applied for 30 minutes with the pump on and In place. The <br /> water was then shut off and the pump was allowed to run for an additional 30 minutes. <br /> The test mannequin (Timmy) was then placed upon the safety cover. At the end of 3 <br /> minutes after placing Timmy upon the safety cover, an unsafe amount of water as <br /> described In ASTM ES 13 section 9.3.1 did not exist. The Cover-Pool safety cover met <br /> the safety requirements as outlined in ASTM ES 13 section 7.3. <br /> All safety covers and equipment tested were standard as provided by Cover-Pools Inc. Safety covers <br /> were Installed according to Cover-Pdols, Inc. standard installation criteria. <br /> Inspector. Jerry Hall <br /> • <br /> R M'S Me APPUDAKE OU.Y tO f►ftri0 SAl+L61 TESTED. <br /> WORTS WO'NOT eE RIZPOOU(Jc!D.ExeEPY P4 RU..VAISKXTT <br /> WRITTEN PEASIISSKSI BY PSI.V4C. <br /> Respectfully submitted, <br /> Professional Service industries, Inc. <br /> Jerry G. Hatt <br /> Department Manager <br /> • <br /> • <br /> TOTAL P.02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.