Laserfiche WebLink
Section E <br /> Make-up air <br /> Passive (determined from calculations from Table 501.3.1) <br /> Powered(determined from calculations from Table 501.3.1) <br /> Interlocked with exhaust device(determined from calculation from Table 501.3.1) <br /> Q Other,describe: <br /> Location of duct or system ventilation make-up air: Determined from make-up air opening table <br /> Cfin I NA Size and type(round,rectangular,flex or rigid) <br /> Directions-In order to determine the makeup air, Table 501.3.1 must be filled out(see below). For most new <br /> installations, column A will be appropriate, however, if atmospherically vented appliances or solid fuel appliances are <br /> installed, use the appropriate column. For existing dwellings,see INC 501.3.3. Please note, if the makeup air quantity <br /> is negative, no additional makeup air will be re-quired for ventilation, if the value is positive refer to Table 501.3.2 and <br /> size the opening. Transfer the cfm, size of opening and type(round, rectangular, flex or rigid)to the last line of section D. <br /> The make-up air supply must be installed per IMC 501.3.2.3. <br /> Table 501.3.1 <br /> PROCEDURE TO DETERMINE MAKEUP AIR QUANITY FOR EXHAUST EQUIPMENT IN DWELLINGS <br /> (Additional combustion air will be required for combustion appliances,see KAIR method for aakx9ations) <br /> One or multiple power One or multiple fan One atmospherically vent Multiple atmospherically <br /> vent or direct vent assisted appliances and gas or oil appliance or vented gas or oil applia <br /> ncet <br /> appliances or no power vent or direct one solid fuel appliance or solid fuel appliances <br /> combustion appliances vent appliances <br /> Column A Column B Column <br /> 1. <br /> a)pressure factor(cfrrdsf) 0.15 0.09 0.06 0.03 <br /> b)conditioned floor area(sf) <br /> _(including unfinished basements) 1473 <br /> Estimated mHouse Infiltration(dm): 221 <br /> 2.Exhaust Capacity <br /> a)continuous exhaust-only Balanced <br /> ventilation system(cfm);(not <br /> applicable to balanced ventilation <br /> systems such as HRV) <br /> b)clothes dryer(dm) 135 135 135 <br /> 135 <br /> C)80%of largest exhaust rating(dm); <br /> Kitchen hood typically(not applicable Less than <br /> if recirculating system or N powered 300Cfm <br /> makeup air is electrically interlocked <br /> and match to exhaust) <br /> d)80%of next largest exhaust rating <br /> (cfm); bath fan typically(not Not <br /> applicable if recirculating system or if <br /> powered makeup air is electrically Applicable <br /> interlocked and matched to exhaust) <br /> Total Exhaust Capacity(dm); <br /> 2a+2b+2c+2 <br /> 3.Makeup Air Quantity(dm) <br /> a)total exhaust capacity(from above) <br /> b)estimated house infift0on(from <br /> above) <br /> Makeup Air Quantity(cam); <br /> (3a—3b)(if value is negative,no <br /> makeup air is needed <br /> 4.For makeup Air Opening Sizing, <br /> refer to Table 501.4.2 NR <br /> A. Use this column if there are other than fan-assisted or atmospherically vented gas or oil appliance or if there are no combustion appliances.(Power <br /> vent and direct vent appliances may be used.) <br /> B. Use this column if there is one fan-assisted appliance per venting system.(Appliances other than atmospherically vented appliances may be included.) <br /> C. Use this column if there is one atmospherically vented(other than fan-assisted)gas or oil appliance per venting system or one solid fuel appliance. <br /> D. Use this column if there are multiple atmospherically vented gas or oil appliances using a common vent or if there are atmospherically vented gas or <br /> oil appliances and solid hued appliances. <br /> 3 <br />