My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2005 - P09111 - new septic
Orono
>
Property Files
>
Street Address
>
W
>
Willowbrook Drive
>
1101 Willowbrook Dr - 26-118-23-41-0003
>
Septic
>
2005 - P09111 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:18:29 PM
Creation date
2/19/2020 10:06:17 AM
Metadata
Fields
Template:
x Address Old
House Number
1101
Street Name
Willowbrook
Street Type
Drive
Address
1101 Willowbrook Drive
Document Type
Septic
PIN
2611823410003
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The manifold and supply line pipe must have back drainage to the pumping chamber. <br /> The distribution pipes shall have their ends capped. Be sure the rock and sand fill <br /> material are clean. The sod layer below the entire mounded area must be turned over, <br /> just break up the sod, be sure not to over work. <br /> All neighboring wells are located greater than 100' away from the proposed treatment <br /> area. <br /> Keep all heavy equipment off of the proposed treatment area before and after <br /> construction. The treatment area should be marked off before construction. This <br /> Design is not valid & the system will need to be relocated if failure to protect the areas <br /> proposed for On-Site Sewage Treatment occurs. <br /> With proper installation and maintenance, this system should have no problem in <br /> treating septic effluent effectively. <br /> Nothing other than human waste, toilet tissue, laundry, showers, water softener etc. <br /> should be disposed of into the septic tanks. Iron filters must be diverted out of the <br /> system. Recommend to divert the water softner also. Garbage disposals are not <br /> recommended, due to adding more solids & fine solids passing through to the system. <br /> Excessive amounts of soaps, antibacterial soaps, cleaning agents, shower cleaners <br /> used every shower & chlorine agents may kill the bacteria needed to treat septic <br /> effluent. Additives are not recommended. Recommend to pump & clean your tanks <br /> through the manhole by a certified pumper every 2 years. Check with your pumper to <br /> set up a schedule. <br /> Steven B. Schirmers <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.