Laserfiche WebLink
200420 KIT/DIN WALL <br /> 14L)-- Titt4AIV: <br /> TJ-BeamTM v5.55 Serial Number:700103477 2 Pcs of 1.75" x 9.5" 2.0E Microllam® LVL <br /> BEAMUSA 1111 12/4/00 2:39 24 PM <br /> Page 1 of 1 Build Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 1 � �2 <br /> 8'6" <br /> Product Diagram Is Conceptual. <br /> LOADS: <br /> Analysis for Beam Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration; 15 Dead;0 Partition; and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Tapered(plf) Floor(1.00) 340 to 440 128 to 165 0 to 8'6" Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(lbs.) <br /> WIDTH LENGTH .LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5.25" 4" 1752/697/2449 1 9.5" Detail A3 1.25"LSL Rim <br /> 2 Column 5.25" 4" 1903/753/2657 1 9.5" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(Ib) 2448 1846 6318 Passed(29%) Rt. end Span 1 under Floor loading <br /> Moment(ft-lb) 4658 4658 13156 Passed(35%) MID Span 1 under Floor loading <br /> Live Defl.(in) 0.086 0.262 Passed(U999+) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.120 0.394 Passed(U787) MID Span 1 under Floor loading <br /> -Deflection Criteria: STANDARD(LL: U360,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright m 2000 by Trus Joist,a Weyerhaeuser Business. TJ-Pro"and TJ-BeamTM are trademarks of Trus Joist. <br /> Microllam®is a registered trademark of Trus Joist <br />