2001 - P03485 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Willow View Drive
>
1050 Willow View Dr - 28-118-23-41-0011
>
Permits/Inspections
>
2001 - P03485 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:04 PM
Creation date
2/19/2020 8:22:48 AM
Metadata
Fields
Template:
x Address Old
House Number
1050
Street Name
Willow View
Street Type
Drive
Address
1050 Willow View Drive
Document Type
Permits/Inspections
PIN
2811823410011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
200420 GARAGE DR <br /> TJ-Beam."" v555 Serial Number 700103477 2 Pcs of 1.75 x 9.5 2.0E Microllam® LVL <br /> BEAMUSA 1111 12/4/00 3:30.08 PM <br /> Page 1 of 1 Build Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> Member Slope:0 Roof Slope:0 <br /> I 1 <br /> 2 <br /> 10' <br /> All dimensions are horizontal. Product Diagram Is Conceptual. <br /> LOADS: <br /> Analysis for Beam Member Supporting ROOF Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 125%duration; 15 Dead; and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(plf) Roof(1.25) 180 68 0 to 5'3" Adds to <br /> Uniform(plf) Roof(1.25) 507 190 5'3"to 10' Adds to <br /> Point(Ibs.) Roof(1.25) 0 2052 5'3" Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(lbs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 3.50" 3.5" 1455/1566/3022 1 9.5" Detail R1 SB Shear Blocking <br /> 2 Column 3.50" 3.5" 2298/1987/4285 1 9.5" Detail R1 SB Shear Blocking <br /> -See TJ SPECIFIER'S I BUILDER'S GUIDES for detail(s): R1. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(Ib) 4158 3460 7897 Passed(44%) Rt. end Span 1 under Roof loading <br /> Moment(ft-lb) 11062 11062 16445 Passed(67%) MID Span 1 under Roof loading <br /> Live Defl.(in) 0.161 0.322 Passed(L1722) MID Span 1 under Roof loading <br /> Total Defl.(in) 0.375 0.483 Passed(U310) MID Span 1 under Roof loading <br /> -Deflection Criteria: STANDARD(LL: U360,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> -Design assumes adequate continuous lateral support of the compression edge. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection: <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright©2000 by Trus Joist,a Weyerhaeuser Business. TJ-Beam^"is a trademark of Trus Joist. <br /> Microllam®is a registered trademark of Trus Joist. <br />