My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 - P03485 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Willow View Drive
>
1050 Willow View Dr - 28-118-23-41-0011
>
Permits/Inspections
>
2001 - P03485 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:04 PM
Creation date
2/19/2020 8:22:48 AM
Metadata
Fields
Template:
x Address Old
House Number
1050
Street Name
Willow View
Street Type
Drive
Address
1050 Willow View Drive
Document Type
Permits/Inspections
PIN
2811823410011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�y� G�J7 200420 FOYER/DINING <br /> P.77Zi LATJ-Bean v5.55 Serial Number:700103477 2 Pcs of 1.75" x 11.875" 2.0E Microllam® LVL <br /> BEAMUSA 1111 12/7/00 7:43.42 AM <br /> Page 1 of 1 Build Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 13' <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration; 15 Dead; 0 Partition;and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Tapered(plf) Floor(1.00) 40 to 240 15 to 90 0 to 8' Adds to <br /> Tapered(plf) Floor(1.00) 240 to 300 90 to 113 8'to 13' Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(Ibs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5.25" 4" 1190/521 /1710 1 11.9" Detail A3 1.25"LSL Rim <br /> 2 Column 5.25" 4" 1800/751 /2551 1 11.9" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(lb) 2402 1884 7897 Passed(24%) Rt. end Span 1 under Floor loading <br /> Moment(ft-lb) 6504 6504 19942 Passed(33%) MID Span 1 under Floor loading <br /> Live Defl.(in) 0.140 0.309 Passed(U999+) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.199 0.619 Passed(Ll744) MID Span 1 under Floor loading <br /> -Deflection Criteria: STANDARD(LL: U480,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright C 2000 by Trus Joist,a Weyerhaeuser Business. TJ-Pro^"and TJ-Beam""are trademarks of Trus Joist <br /> Microllarr>®is a registered trademark of Trus Joist. <br />
The URL can be used to link to this page
Your browser does not support the video tag.