Laserfiche WebLink
r r <br /> ENERGY CODE DESIGN BY ACCEPTABLE PRACTICE <br /> To Determine Compliance with the Minnesota Energy Code <br /> (Section 602 of the State Amended 1983 Model Energy Code) <br /> This form is oily applicable do detached one-and two-family dwellings. The requirements herei <br /> are based cn Table No. 6-11 in lieu of the criteria specified in Sections 602.2.1, .2 and .3. <br /> Building Address <br /> Contractor or Owner <br /> Building Element "R" Values Area (sq ft) of Ext. Walls <br /> Ceilings Design Req'd 38 <br /> Walls (exterior) Design Req'd 20 <br /> (w/o fdn) <br /> Floors (over unheated spaces) Design Req'd 20 <br /> *Windows (in bldgs w/o Design Req'd 12 <br /> sliding glass door) (glass) <br /> *Windows (in bldgs with a Design Req'd 10 <br /> sliding glass door) (glass) <br /> Foundation Walls Design Req'd 5 (when insulating full depth of <br /> foundaticn wall) <br /> Design Req'd 10 (when insulating only to frost <br /> depth and footings extend below) <br /> Slab-cm-grade floors Design Req'd (See Figure No. 3) <br /> **Doors (1-3/4" metal faced) Design Req'd 3 <br /> * All windows shall be double glazed or have storm windows <br /> ** Conventional doors other than metal require a storm door <br /> 10�rjLF KATION <br /> I hereby certify that I have coapleted the above information and that it complies with the <br /> Minnesota State Energy Code. <br /> Signature Date <br /> BCSD 3-89 15 <br /> CC/SM/6593 <br />