Laserfiche WebLink
• <br /> 4 SEAS FOUND <br /> TJ-Beam'' .r5 55s SerialNumber700103477 2 Pcs of 1.75" x 9.5" 2.0E Microilam® L IL <br /> BEAMUSA 1111 2/20/02 3.58 28 PM <br /> Page 1 a 1 Build Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 12'6" • <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration;15 Dead;0 Partition;and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(plf) Floor(1.00) 250 94 0 to'12'6" Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(lbs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5.50" 4.25" 1812/739/2551 1 9.5" Detail A3 1.25"LSL Rim <br /> 2 Column 5.50" 4.25" 1812/739/2551 1 9.5" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S 1 BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: • <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(lb) 2415 2041 6318 Passed(32%) Lt.end Span 1 under Floor loading <br /> Moment(ft-Ib) 7145 7145 13156 Passed(54%) MID Span 1 under Floor loading <br /> Live Defl.(in) 0.273 0.296 Passed(U519) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.385 0.592 Passed(L/369) MID Span 1 under Floor loading <br /> -Deflection Criteria:STANDARD(LL:U480,TL:L/240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ wan-ants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright C 2000 by Trus Joist,a Weyerhaeuser Business. TJ-Pro"and TJ-BeamT"are trademarks of Trus Joist. <br /> Microllamm is a registered trademark cf Trus Jar <br />