Laserfiche WebLink
BED 2 WDW <br /> TJ-Beam• y.55 Serial Number.700103477 2 Pcs of 1.75 x 9.5 2.0E Microllan'® LVL <br /> BAMUSA 1111 2120/02 11.16:16 AM <br /> Page 1 of 1 Build Code.146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> Member Slope:0 Roof Slope:0 <br /> 1 <br /> 1 <br /> 1111111. <br /> 5'8"_ <br /> All dimensions are horizontal. Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Beam Member Supporting ROOF Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 125%duration;15 Dead;and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(plf) Roof(1.25) 780 293 0 to 3'6" Adds to <br /> Uniform(pff) Roof(1.25) 180 68 3'6"to 5'8" Adds to <br /> Point(Ibs.) Roof(1.25) 0 2984 3'6" Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(Ibs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5.25" 5.25" 2119/1919/4038 1 9.5" Detail R1 SB Shear Blocking <br /> 2 Column 5.25" 5.25" 1228/2374/3602 1 9.5" Detail R1 SB Shear Blocking <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):R1. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(Ib) 3683 3219 7897 Passed(41%) Rt.end Span 1 under Roof loading <br /> Moment(ft-lb) 5962 5962 16445 Passed(36%) MID Span 1 under Roof loading <br /> Live Defl.(in) 0.026 0.168 Passed(U999+) MID Span 1 under Roof loading <br /> Total Defl.(in) 0.071 0.252 Passed(U856) MID Span 1 under Roof loading <br /> -Deflection Criteria: STANDARD(LL: U360,TL:L1240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> -Design assumes adequate continuous lateral support of the compression edge. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code.UBC analyzing the TJ Residential product listed above. <br /> -Note:See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright®2000 by Trus Joist,a Weyerhaeuser Business. TJ-Beam'"is a trademark of Trus Joist. <br /> Microllam®is a registered trademark of Trus Joist <br />