Laserfiche WebLink
t <br /> M2198 BBQ DECK <br /> T,a,,,,OM8.02S,; ,"� 7M,601 51/4" x 14" 2.0E Parallam@ PSL, CCA-SL 2 (190/6 < MC < 28%) <br /> Uww.z 6,ZW9,30:2eAM <br /> Pagel Eninevengon:1.21 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN <br /> -CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 0 <br /> 8 7F 6" 1 <br /> Product Dkgrsrn is Conceptual. <br /> LOADS: <br /> Analysis is for a Drop Beam Member. Tributary Load Width:1' <br /> Primary Load Group-Residential-Living Areas(psf):40.0 Live at 100%duration,15.0 Dead <br /> Vertical Loads: <br /> Type Class Live Dead Location Application Comment <br /> Uniform(plf) Floor(1.00) 480.0 180.0 0 To 9 Adds To <br /> Tapered(plf) Floor(1.00) 280.0 To 210.0 105.0 To 79.0 9 To 17 6' Adds To <br /> (1) Pointpbs) Floor(1.00) 0 2771 3" - <br /> Point(Ibs) Floor(1.00) 0 4813 4'9' - <br /> Point(lbs) Floor(1.00) 0 2771 8'9" - <br /> -(1)Analysis assumes loads are passed through to support: Sufficient strength full depth bkidting,rim or squash blocks are required at support(s):1 The <br /> a�essories shown,at the diagram above,have NOT been checked for capacity. Downward acting point loads are included in the reported SUPPORT(S) <br /> reactions. These are the reactions aswith the highest coefficient of duration and may not be the most CRITICAL c ase when designing the <br /> supporting member below. <br /> SUPPORTS: <br /> Input Bearing Vertical Reactions pbs) Pty Depth Nailing Detail Other <br /> Width Length Live/Dead/UpINVTotal Depth <br /> 1 Wood column 5.25' 8.30' 3130/7863/0/10993 WA WA WA L5 None <br /> 2 Parailam PSL Beam 5.25" 5.63" 2548/4908/0/7456 1 16.00" WA L3:Top Mount Hanger None <br /> -See TJ SPECIFIER'S/BUILDERS GUIDE for detail(s):L5,L3:Top Mount Hanger <br /> -Bearing length requirement exceeds input at support(s)1.Supplemental hardware is required to satisfy bearing requirements. <br /> HANGERS:Simpson Strong Tie®Connectors <br /> Support Model Slope Skew Reverse Top Flange Top Flange Support Wood <br /> Flanges Offset Slope Species <br /> 2 L3:Top Mount Hanger NONE FOUND 0112 0 WA WA WA WA <br /> PROJECT INFORMATION: OPERATOR INFORMATION: <br /> TERRY MIKKELSON <br /> DFP PLANNING 8 DESIGN <br /> 4797 HWY 10 <br /> ARDEN HILLS,MN 55112 <br /> Phone:65146364889 <br /> Fax :651-638-1412 <br /> PLANNINGDESIGN@EMAIL.MSN.COM <br /> Copyright O 2001 by Trus Joist, a Weyerhaeuser Business <br /> Parallam®and Parallame are registered trademarks of Trus Joist. <br /> Simpson Strong-Ties Connectors is a registered trademark of Simpson Strong-Tie Company, Inc. <br />