Laserfiche WebLink
' RHVVC-Residential&Light Commercial HVAC Loads Program F Elite Software Development,Inc. <br /> Flare Heating&NC Inc. ' Medina Model-2 Story <br /> Golden Valley,MN 55427-3700 ` 11-17-2000 Page 1 <br /> Project Summary <br /> Company: Flare Heating &Air Conditioning <br /> Client: RVC Homes Representative: Gregg <br /> Address: 1003 12 Oaks Center- 15500 Address: 9303 Plymouth Ave. N. <br /> Wayzata Blvd. <br /> City: Wayzata, Mn. 55391 City: Golden Valley, Minnesota 55427 <br /> Phone: 952-473-6721 Phone: 763-542-1166 <br /> Fax: 952-473-6725 Fax: 763-542-3101 <br /> Comment: You Can Feel The Difference <br /> Design Data <br /> Project Name: Medina Model- 2 Story <br /> Reference City: Minneapolis, Minnesota <br /> Daily Temperature Range: Medium <br /> Latitude: 44 Degrees <br /> Elevation: 834 Feet <br /> Outdoor Outdoor Indoor Indoor Grains <br /> Dry Bulb Wet Bulb Rel.Hum. Dry Bulb Difference <br /> Winter: -20 N/A N/A 72 N/A <br /> Summer: 95 75 50% 75 36 <br /> Check Figures <br /> Total Building Supply CFM: 1637 CFM per square foot: 0.322 <br /> Square feet of room area: 5,079 Square feet per ton: 1,179.091 <br /> Building Loads <br /> Total heating required with outside air: 97,403 Btuh 97.403 MBH <br /> Total sensible gain: 38,768 Btuh 82 % <br /> Total latent gain: 8,638 Btuh 18 % <br /> Total cooling required with outside air: 47,406 Btuh 3.951 Tons (based on sensible + latent) <br /> 4.308 Tons (based on 75% sensible capacity) <br /> Notes <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Friday,November 17,2000 <br />