Ithvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. <br /> Angell-Aire ii <br /> Model 5(1005 Willow View Drive) <br /> BumsviUe,MN 56337 Page 2 <br /> System <br /> p 1 (Imported) Summary Loads <br /> 5$, j¢l).':;"?ol jl: rte I-. ,, '1 -T:r 4 t f <br /> O <br /> t y !, F <br /> tt L 1ti tih@ �4k <br /> 3A-w-o: Glazing-Double pane low-e (e= 0.40), operable 519 25,307 0 33,111 33,111 <br /> window,wood frame <br /> 11P: Door-Polyurethane Core 42 1,121 0 414 414 <br /> 12E-Osw: Wall-Frame, R-19 insulation in 2 x 6 stud cavity, 3650 22,834 0 6,305 6,305 <br /> no board insulation,siding finish,wood studs <br /> 15A11-0ocw-8: Wall-Basement, , framing with R-11 sill to 801 4,245 0 188 188 <br /> floor in 2 x 4 cavity, open core, no board insulation, <br /> plus interior finish,wood studs, 8'floor depth <br /> 16B-44: Roof/Ceiling-Under attic or knee wall,Vented 674 1,364 0 860 860 <br /> Attic, No Radiant Barrier, Dark Asphalt Shingles or <br /> Dark Metal, Tar and Gravel or Membrane, R-44 <br /> insulation <br /> 16CR-44: Roof/Ceiling-Under attic or knee wall,Vented 1530 3,007 0 1,616 1,616 <br /> Attic with Radiant Barrier, Dark Asphalt Shingles or <br /> Dark Metal,Tar and Gravel or Membrane, R-44 - <br /> insulation <br /> 21B-32: Floor-Basement, Concrete slab, any thickness,2 2478 3,192 0 0 0 <br /> or more feet below grade, R-3 or higher insulation <br /> installed below floor, any floor cover,shortest side of <br /> floor slab is 32'wide <br /> 20P-19: Floor-Over open crawl space or garage, Passive, 414 1,904 0 373 373 <br /> R-19 blanket insulation, any cover <br /> Subtotals for structure: 63,064 0 42,867 42,867 <br /> People: 4 920 1,200 2,120 <br /> Equipment: 0 0 0 <br /> Lighting: 0 0 0 <br /> Ductwork: 0 0 0 0 <br /> Infiltration: Winter CFM: 200, Summer CFM: 115 19,651 1,861 2,835 4,696 <br /> Ventilation: Winter CFM: 90, Summer CFM: 90 8,802 1,444 2,200 3,645 <br /> AED Excursion: 0 0 6,277 6,277 <br /> System 1 (Imported) Load Totals: 91,517 4,225 55,379 59,604 <br /> r«LP' «�`��it'I' _ .t-.., s .s Hr o t r• L. •^> ,nr rr, E. <br /> Supply CFM: 2,491 CFM Per Square ft.: • 0.402 <br /> Square ft. of Room Area: 6,192 Square ft. Per Ton: 1,033 <br /> Volume (ft3) of Cond. Space: 53,764 Air Turnover Rate (per hour): 2.8 <br /> L..P L7.:1r 4...a :7.d::(= <br /> Total Heating Required With Outside Air: 91,517 Btuh 91.517 MBH <br /> Total Sensible Gain: 55,379 Btuh 93 <br /> Total Latent Gain: 4,225 Btuh 7 % <br /> Total Cooling Required thlith Outside Air: 59,604 Btuh 4.97 Tons (Based On Sensible + Latent) <br /> 5.99 Tons(Based On 77% Sensible Capacity) <br /> Calculations are based on 8th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br />