My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Onsite sewage treatment system
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive South
>
0440 Willow Dr S - 03-117-23-32-0011
>
Septic
>
Onsite sewage treatment system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 3:10:54 PM
Creation date
2/18/2020 11:44:14 AM
Metadata
Fields
Template:
x Address Old
Address
0440 Willow Dr S
Document Type
Septic
PIN
0311723320011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO O <br /> Municipal Offices O O <br /> Post Office Box 66 <br /> Crystal Bay, MN 55323-0066 ON—SITE SEWAGE TREATMENT <br /> INSPECTION REPORT <br /> ti <br /> ��9kESH.O��G <br /> r ��a l ���.J 1)6 Owner: Address: � <br /> Permit #'s: 20nP. Dates: Contractors: `zjym,- gyros, ? <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. <br /> (This is P41 an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the Location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with Less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The Limiting soil characteristic;K has or I ) has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): <br /> Tank inspection indicates: <br /> 5 Pumpout not needed at this time. <br /> 6 Solids accumulation in tanks indicates they should be pumped out this year to help prevent future problems. <br /> 7 Solids accumulation in tanks is at a critical level. 'tanks should be pumped out as soon as possible. <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next punpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): <br /> Dr-infield inspection indicates: <br /> Drainfield is dry, no surfacing evident. <br /> Some evidence of surfacing, not critical yet. <br /> "`TTT333 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope.setbacks.etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (der)ends on soils,water table.etc.): <br /> I <br /> COMMENTS: <br /> a4!445 4= 9fa4 Q <br /> Date of Inspection Teptic System Ingipector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.