My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 - P03933 - mechanical
Orono
>
Property Files
>
Street Address
>
W
>
Willow View Drive
>
0990 Willow View Dr - 28-118-23-41-0014
>
Permits/Inspections
>
2001 - P03933 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:25:15 PM
Creation date
2/18/2020 11:19:08 AM
Metadata
Fields
Template:
x Address Old
House Number
990
Street Name
Willow View
Street Type
Drive
Address
990 Willow View Drive
Document Type
Permits/Inspections
PIN
2811823410014
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RHVAC-residential&Light Commercial HVAC Loads Program is,. Elite Software Development,Inc. <br /> Angell-Aire ORONO <br /> Eagan,MN 55123 06-06-2001 Page 2 <br /> System#1 Summary Loads <br /> Component Area Sen. Lat. Sen. Total <br /> Description Quan Loss Gain Gain Gain <br /> 3D Window Double Pane Low Emit Wood Frame 177 5,623 0 11,328 11,328 <br /> 12H Wall R-19+ 1/2"Gypsum Board(R-0.5) 754 3,981 0 1,067 1,067 <br /> 15G Wall 5'or More Below Grade 8/12" Blk+R-11 1,327 5,021 0 0 0 <br /> 21A Basemt Floor 2'or More Below Grade 2,280 4,815 0 0 0 <br /> Subtotals for structure: 4,538 19,440 0 12,395 12,395 <br /> Active People: 0 0 0 0 0 <br /> Inactive People: 0 0 0 0 0 <br /> Appliances: 0 0 0 0 0 <br /> Lighting: 0 0 0 0 0 <br /> Ductwork: 0 0 0 0 0 <br /> Infiltration:Winter CFM: 108.3, Summer CFM: 72.2 177 10,171 1,714 1,541 3,255 <br /> Ventilation: Winter CFM: 36.1, Summer CFM: 36.1 0 3,390 857 771 1,628 <br /> Sensible Gain Total: 14,707 <br /> Temperature Swing Multiplier. X1.00 <br /> System Load Totals: 33,001 2,571 14,707 17,278 <br /> r41ecw-Figul : ---: A n . <br /> Supply CFM: 653 CFM per square foot: 0.286 <br /> Square feet of room area: 2,280 Square feet per ton: 1,432.504 <br /> 8ti } <br /> Total heating required with outside air: 33,001 Btuh 33.001 MBH <br /> Total sensible gain: 14,707 Btuh 85 % <br /> Total latent gain: 2,571 Btuh 15 % <br /> Total cooling required with outside air: 17,278 Btuh 1.44 Tons(based on sensible+ latent) <br /> 1.592 Tons(based on 77%sensible capacity) <br /> Calculations are based on 7th edition of ACCA Manual J. <br /> All computed results are estimates as building use and weather may vary. <br /> Be sure to select a unit that meets both sensible and latent loads. <br /> Wednesday,June 06,2001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.