Laserfiche WebLink
203608 MEDIA WDW <br /> AW'everhxucer&mnxls 3 Pcs of 1 3/4" x 9 1/2" 2.0E Parallam® PSL <br /> • <br /> TJ-Beam(TM)6.10 Serial Number 7003009804 <br /> User:1 1/22/2004 8:55:56 AM <br /> Page Engine Version:1.10.3 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN <br /> CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 6 12' b <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis is for a Drop Beam Member. Tributary Load Width:1' <br /> Primary Load Group-Residential-Living Areas(psf):40.0 Live at 100%duration,15.0 Dead <br /> Vertical Loads: <br /> Type Class Live Dead Location Application Comment <br /> Uniform(plf) Floor(1.00) 360.0 135.0 0 To 12' Adds To <br /> Point(lbs) Floor(1.00) 0 11265 3" - <br /> Point(lbs) Floor(1.00) 0 10826 11'9" - <br /> SUPPORTS: <br /> Input Bearing Vertical Reactions(lbs) Detail Other <br /> Width Length Live/Dead/Uplift/Total <br /> 1 Wood column 5.25" 5.25" 2400/12258/0/14658 L1:Blocking Custom Blocking <br /> 2 Wood column 5.25" 5.25" 2400/11819/0/14219 L1:Blocking Custom Blocking <br /> -See TJ SPECIFIER'S/BUILDERS GUIDE for detail(s):L1:Blocking <br /> DESIGN CONTROLS: <br /> Maximum Design Control Control Location <br /> Shear(lbs) 3217 -2698 9642 Passed(28%) Rt.end Span 1 under Floor loading <br /> Moment(Ft-Lbs) 9148 9148 19585 Passed(47%) MID Span 1 under Floor loading <br /> Live Load Defl(in) 0.216 0.379 Passed(L/633) MID Span 1 under Floor loading <br /> Total Load Defl(in) 0.305 0.569 Passed(L/447) MID Span 1 under Floor loading <br /> -Deflection Criteria:STANDARD(LL:L/360,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and positioning of lateral <br /> bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this software will be <br /> accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application,input design loads,and <br /> stated dimensions have been provided by the software user. This output has not been reviewed by a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Building Code UBC analyzing the TJ Distribution product listed above. <br /> -Note:See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION: OPERATOR INFORMATION: <br /> TERRY MIKKELSON <br /> DFP PLANNING&DESIGN <br /> 9100 BALTIMORE ST.NE <br /> SUITE 106 <br /> BLAINE,MN 55449 <br /> Phone:(763)780-8004 <br /> Fax :(763)780-8015 <br /> DFPPLANNINGDESIGN@VISI.COM <br /> Copyright © 2003 by Trus Joist, a Weyr=rha,user Business <br /> Parallam® is a registered trademark of Trus Joist. <br />