Laserfiche WebLink
BSMT PATIO DR <br /> * Wt/?C/W/11oeit i jai . <br /> T4,-8eam'" x5.42 Serial Number:709046244 3 Pcs 011.75" x 9.5" 2.0E Microllam® LVL <br /> BEAMUSA 1111 4/30199 15:47:22 <br /> Paye 1 of 1 Build Cade:104 • <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> • I 1 <br /> • Fr • Jiil. ; . , <br /> 7' <br /> Product Diagram is Conceptual. <br /> LOADS: i <br /> Analysis for Beam Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration,15 Dead,0 Partition,and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(plf) Floor(1.00) 380 •'143 0 to 7'.- Adds to <br /> Uniform(plf) Floor(1.00) 380 263 4'9"to 7' Adds to <br /> Point(Ibs.) Floor(1.00) 0 10080 4'9" Adds to <br /> SUPPORTS: INPUT. BEARING REACTIONS(Ibs.) <br /> WIDTH LENGTH JUSTIFICATION LIVE/DEAD/TOTAL DETAIL OTHER <br /> 1 Column 5.25". 4" Left Face 1582/3742/5324 Detail A3 1.25"LSL Rim <br /> 2 Column 5.25" 4" Right Face 2213/8132/10345 Detail A3 1.25"LSL Rim <br /> • <br /> -See TJM SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. - <br /> DESIGN CONTROLS: <br /> , <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(Ib) - 9959 8827 9476 Passed(93%) Rt.end Span 1 under Floor loading <br /> Moment(ft-lb) 16978 16978 • 19734 Passed(86%) MID Span 1 under Floor loading - . • <br /> Live Defl.(in) 0.030 0.213 Passed(U999+) MID Span 1 under Floor loading <br /> . Total Defl.(in) 0.170 0.319 Passed(U450) MID Span 1 under Floor loading • . <br /> Deflection Criteria:STANDARD(LL:U360,TL:U240). <br /> =Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and • . <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist MacMillan(TJM). TJM warrants the sizing of its <br /> products by this software will be accomplished in accordance with TJM product design criteria and code accepted design values. The <br /> specific product application,input design loads, and stated dimensions have been provided by the software user. This output has not <br /> been reviewed by a TJM Associate. <br /> -Not all products are readily available. Check with your supplier or TJM technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST MacMILLAN PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. _ <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJM Residential product listed above. <br /> -Note: See TJM SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> • <br /> PROJECT INFORMATION OPERATOR INFORMATION: • <br /> No Project Information available D.F.P.PLANNING& DESIGN, INC. • <br /> TERRY MIKKELSON <br /> 4797 HIGHWAY 10 N.E. • <br /> ARDEN HILLS, MN 55112 <br /> 651-636-6889 <br /> 651-638-1412 • <br /> Copyright m 1999 by Trus Joist MacMillan,a limited partnership,Boise,Idaho,USA TJ-ProTM and TJ-BeamT"are trademarks of Trus Joist MacMillan. <br /> Microllam®is a registered trademark of Trus Joist MacMillan. • <br />