Laserfiche WebLink
1:31J I I_ttt rt+ly i PCT <br /> iti-We,4Iac/tIilun . <br /> TJ-Beam"' 'v5.42 Serial Number:709046244 2 Pcs of 1.75" x 11.875" 2.0E Microllam® LVL <br /> BEAMUSA 1111 '4130199 14.07:49 • <br /> Page 1 of 1 Build Code:104 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> . • I <br /> 1 <br /> r <br /> 6 6,3., , • <br /> Product Diagram Is Conceptual. <br /> LOADS: - i <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width:1' - <br /> Loads(psf):40 Live at 100%duration,15 Dead,0 Partition,and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(ptf) Floor(1.00) 440 :165 • 0 to 2'10" . Adds to • .. <br /> Uniform(pif) Floor(1.00) 620 233 2'10"to 6'3" Adds to . <br /> Point(Ibs.) Floor(1.00) 0 1005 2'10" Adds to <br /> SUPPORTS: INPUT . BEARING • REACTIONS(Ibs.) . <br /> WIDTH LENGTH JUSTIFICATION LIVE!DEAD!TOTAL DETAIL OTHER <br /> 1 2x4 Plate 3.50" 2.25" • Left Face .1609/1178/2786 Detail A3 1.25"LSL Rim . <br /> 2 2x6 Plate 5.50" 4.25" • Right Face 2006/1257/3263 Detail A3 1.25"LSL Rim . <br /> -See TJM SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: . <br /> MAXIMUM . DESIGN CONTROL . CONTROL - LOCATION • <br /> Shear(Ib) 2956 - 1931 : ..7897 Passed(24%) ... Rt.end Span 1 under Floor loading. ' - <br /> Moment(ft-Ib) • 4744 • 4744 19942 Passed(24%) MID Span 1 under Floor loading ; ' <br /> Live Defl.(in) 0.021 -. 0.144 :•Passed(U999+)'..MID Span 1 under Floor loading <br /> Total Defl.(in) 0.040 . 0.287 Passed(U999+) MID Span 1 under Floor loading <br /> Deflection Criteria:STANDARD(LL:1J480,TL:U240). <br /> =Bracing(Lu):All compression'edges(top and bottom)must be braced at 2'8".o/c unless detailed otherwise.:Proper attachment and- <br /> positioning of lateral bracing is required to achieve member stability.• <br /> ADDITIONAL NOTES: V <br /> • <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist MacMillan(TJM). TJM warrants the sizing of its , <br /> products by this software will be accomplished in accordance with TJM product design criteria and code accepted design values. The <br /> specific product application,input design loads,and stated dimensions have been provided by the software user. This output has not <br /> been reviewed by a TJM Associate. <br /> -Not all products are readily available. Check with your supplier or TJM technical representative for product availability. • <br /> -THIS ANALYSIS FOR TRUS JOIST MacMILLAN PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. • • <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJM Residential product listed above. <br /> -Note: See TJM SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> • <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P.PLANNING&DESIGN,INC. <br /> TERRY MIKKELSON <br /> 4797 HIGHWAY 10 N.E. . <br /> ARDEN HILLS, MN 55112 <br /> 651-636-6889 <br /> 651-638-1412 ' <br /> Copyright©1999 by Trus Joist MacMitlan,a limited partnership,Boise,Idaho,USA.' TJ-Pro"'and TJ-Beam""are trademarks of Trus Joist MacMillan. <br /> Microllam®is a registered trademark of Trus Joist MacMillan. •• <br />