Laserfiche WebLink
2.U114t3 lVl/A I VVUVV <br /> TJ-Beam'' '555 Serial Number.700103477 2 Pcs of 1.75" x 9.5" 2.0E Microllam® LVL <br /> 8EAMUSA 1111 4/20/01 4.29.55 PM <br /> Page 1 of 1 Build Code.146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> Member Slope:0 Roof Slope:0 <br /> 1 � <br /> X14 <br /> 5,W. <br /> All dimensions are horizontal. Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Beam Member Supporting ROOF Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 125%duration;15 Dead; and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(plf) Roof(1.25) 180 68 0 to 3' Adds to <br /> Uniform(plf) Roof(1.25) 703 264 3'to 4'6" Adds to <br /> Uniform(plf) Roof(1.25) 730 274 4'6"to 5'8" Adds to <br /> Point(lbs.) Roof(1.25) 0 4949 3' Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(Ibs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5-25" 5.25" 913/2681 /3593 1 9.5" Detail R1 SB Shear Blocking <br /> 2 Column 5.25" 5.25" 1760/3325/5085 1 9.5" Detail R1 SB Shear Blocking <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s): R1. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(lb) 4751 2959 5686 Passed(52%) Rt. end Span 1 under Dead load <br /> Moment(ft-lb) 8267 6794 11840 Passed(57%) MID Span 1 under Dead load <br /> Live Defl.(in) 0.018 0.168 Passed(U999+) MID Span 1 under Roof loading <br /> Total Defl.(in) 0.092 0.252 Passed(U660) MID Span 1 under Roof loading <br /> -Deflection Criteria: STANDARD(LL: L/360,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> -Design assumes adequate continuous lateral support of the compression edge. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright®2000 by Trus Joist,a Weyerhaeuser Business. TJ-Beam""is a trademark of Trus Joist. <br /> Microllam®is a registered trademark of Trus Joist <br />