My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 - P04014 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Willow View Drive
>
0950 Willow View Dr - 28-118-23-44-0017
>
Permits/Inspections
>
2001 - P04014 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:26:28 PM
Creation date
2/14/2020 1:41:42 PM
Metadata
Fields
Template:
x Address Old
House Number
950
Street Name
Willow View
Street Type
Drive
Address
950 Willow View Drive
Document Type
Permits/Inspections
PIN
2811823440017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
qedre_ 201148 LAUND WDW <br /> ,TJ-Beam'" v5.55 Serial Number:700103477 2 Pcs of 1.75" x 9.5" 2.0E Microllam® LVL <br /> BEAMUSA. 1111 4/23/01 11:33.36 AM <br /> Page 1 of 1 Build Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 6"— <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Beam Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration; 15 Dead; 0 Partition; and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(plf) Floor(1.00) 330 124 0 to 3'6" Adds to <br /> Uniform(plf) Roof(1.25) 800 420 6"to 3'6" Adds to <br /> Point(Ibs.) Roof(1.25) 0 3680 6" Adds to <br /> Point(Ibs.) Roof(1.25) 0 3734 1' Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(Ibs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5.25" 4" 1652/7068/8720 1 9.5" Detail A3 1.25"LSL Rim <br /> 2 Column 5.25" 4" 2043/2125/4167 1 9.5" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(lb) 8558 2031 7897 Passed(26%) Rt. end Span 1 under Roof loading <br /> Moment(ft-Ib) 3778 2900 11840 Passed(24%) MID Span 1 under Dead load <br /> Live Defl.(in) 0.008 0.096 Passed(U999+) MID Span 1 under Roof loading <br /> Total Defl.(in) 0.023 0.144 Passed(U999+) MID Span 1 under Roof loading <br /> -Deflection Criteria: STANDARD(LL: U360,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright®2000 by Trus Joist,a Weyerhaeuser Business. TJ-ProTM and TJ-Beam"are trademarks of Trus Joist. <br /> Microllam®is a registered trademark of Trus Joist. <br />
The URL can be used to link to this page
Your browser does not support the video tag.