My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001 - P04014 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Willow View Drive
>
0950 Willow View Dr - 28-118-23-44-0017
>
Permits/Inspections
>
2001 - P04014 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:26:28 PM
Creation date
2/14/2020 1:41:42 PM
Metadata
Fields
Template:
x Address Old
House Number
950
Street Name
Willow View
Street Type
Drive
Address
950 Willow View Drive
Document Type
Permits/Inspections
PIN
2811823440017
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. � � 2U114b CCK I KM LEI-I <br /> TJ-Beam'' v5.55 Serial Number:700103477 2 Pcs of 1.75" x 11.875" 2.0E Microllam® LVL <br /> 'BEAMUSA• 1111 4123101 9:40.05 AM <br /> Page 1 of 1 Build Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 4- <br /> 19' <br /> 19' 10" <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration; 15 Dead; 0 Partition; and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(plf) Floor(1.00) 54 20 0 to 19' 10" Adds to <br /> Point(lbs.) Floor(1.00) 0 1272 15' Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(lbs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Column 5.25" 4" 939/771 /1710 1 11.9" Detail A3 1.25"LSL Rim <br /> 2 Column 3.50" 2.25" 925/1423/2348 1 11.9" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(lb) 2325 2168 7897 Passed(27%) Rt. end Span 1 under Floor loading <br /> Moment(ft-Ib) 9880 9880 19942 Passed(50%) MID Span 1 under Floor loading <br /> Live Defl.(in) 0.316 0.484 Passed(U735) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.709 0.968 Passed(U328) MID Span 1 under Floor loading <br /> -Deflection Criteria: STANDARD(LL: L/480,TL:U240). <br /> -Bracing(Lu):All compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright©2000 by Trus Joist,a Weyerhaeuser Business. TJ-Pro''and TJ-Beam''are trademarks of Trus Joist. <br /> Microllam®is a registered trademark of Trus Joist. <br />
The URL can be used to link to this page
Your browser does not support the video tag.