Laserfiche WebLink
BSMT <br /> TJ-BeamT" v5.55 Serial Number:700103477 3 Pcs of 1.75" x 11.875" 2.0E Microllam® LVL <br /> BEt1MUSA 1111 3/4/02 3:45.17 PM <br /> Page 1 of 1 Build Code:146 <br /> THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED <br /> 0 14'6" <br /> Product Diagram is Conceptual. <br /> LOADS: <br /> Analysis for Header Member Supporting FLOOR-RES.Application. Tributary Load Width: 1' <br /> Loads(psf):40 Live at 100%duration;15 Dead;0 Partition;and: <br /> TYPE CLASS LIVE DEAD LOCATION APPLICATION COMMENT <br /> Uniform(ptf) Floor(1.00) 64 24 0 to 14'6" Adds to <br /> Point(lbs.) Floor(1.00) 0 9893 2' Adds to <br /> SUPPORTS: INPUT BEARING REACTIONS(lbs.) <br /> WIDTH LENGTH LIVE/DEAD/TOT. PLY DEPTH DETAIL OTHER <br /> 1 Beam 5.25' 4" 753/9095/9848 1 11.9" Detail A3 1.25'LSL Rim <br /> 2 2x6 Plate 5.50" 4.25" 755/1613/2368 1 11.9" Detail A3 1.25"LSL Rim <br /> -See TJ SPECIFIER'S/BUILDER'S GUIDES for detail(s):A3. <br /> DESIGN CONTROLS: <br /> MAXIMUM DESIGN CONTROL CONTROL LOCATION <br /> Shear(lb) 9798 9015 10661 Passed(85%) Lt end Span 1 under Dead load <br /> Moment(ft-lb) 16306 15238 26922 Passed(57%) MID Span 1 under Dead load <br /> Live Defl.(in) 0.063 0.346 Passed(U999+) MID Span 1 under Floor loading <br /> Total Defl.(in) 0.350 0.693 Passed(U475) MID Span 1 under Floor loading <br /> -Deflection Criteria: STANDARD(LL:U480,TL:U240). <br /> -Bracing(Lu):Al?compression edges(top and bottom)must be braced at 2'8"o/c unless detailed otherwise. Proper attachment and <br /> positioning of lateral bracing is required to achieve member stability. <br /> ADDITIONAL NOTES: <br /> -IMPORTANT! The analysis presented is output from software developed by Trus Joist(TJ). TJ warrants the sizing of its products by this <br /> software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product <br /> application, Input design loads, and stated dimensions have been provided by the software user. This output has not been reviewed by <br /> a TJ Associate. <br /> -Not all products are readily available. Check with your supplier or TJ technical representative for product availability. <br /> -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. <br /> -Allowable Stress Design methodology was used for Code UBC analyzing the TJ Residential product listed above. <br /> -Note: See TJ SPECIFIER'S/BUILDER'S GUIDES for multiple ply connection. <br /> PROJECT INFORMATION OPERATOR INFORMATION: <br /> No Project Information available D.F.P. Planning&Design <br /> Terry Mikkelson <br /> 4797 highway 10 n.e. <br /> arden hills, mn 55112 <br /> 651-636-6889 <br /> 651-638-1412 <br /> Copyright co 2000 oy Trus Joist,a Weyerhaeuser Business. TJ-Pro"and TJ-BeamT"are trademarks of Trus Joist. <br /> Microllam®is a registered trademark of Trus Joist <br />