2014 - Soil & Percolation Testing
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2360 Willow Hill Drive - 03-117-23-23-0023
>
Septic
>
2014 - Soil & Percolation Testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:44 PM
Creation date
2/13/2020 10:24:49 AM
Metadata
Fields
Template:
x Address Old
House Number
2360
Street Name
Willow Hill
Street Type
Drive
Address
2360 Willow Hill Dr
Document Type
Septic
PIN
0311723230023
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Design Summary Worksheet UNIVERSITY <br /> Minnesota Pollution OF MINNESOTA <br /> Control Agency <br /> Mound Design Summary <br /> Absorption Area 625.0 ft2 Bed Length 63.0 ft Bed Width 10.0 ft <br /> Absorption Width 12.0 ft Clean Sand Lift 1.0 ft Berm Width (0-1%) ft <br /> Upslope Berm Width 11.0 ft Downslope Berm Width 15.0 ft Endslope Berm Width 10.0 ft <br /> Total System Length 83.0 ft Total System Width 36.0 ft Contour Loading Rate 12.0 gal/ft <br /> At-Grade Design Summary <br /> Absorption Bed Width ft Absorption Bed Length ft System Height ft <br /> Contour Loading Rate gal/ft Upslope Berm Width ft Downslope Berm Width ft <br /> Endslope Berm Width ft System Length ft System Width ft <br /> Level&Equal Pressure Distribution Summary <br /> No.of Perforated Laterals 3 Perforation Spacing 3 ft Perforation Diameter 7/32 in <br /> Lateral Diameter 2.00 in Min.Delivered Volume 0 gal Maximum Delivered Volume 188 gal <br /> Non-Level and Unequal Pressure Distribution Summary <br /> Elevation Pipe Volume Pipe Length Perforation Size <br /> (ft) Pipe Size(in) (gal/ft) (ft) (in) Spacing(ft) Spacing(in) <br /> Lateral 1 Minimum Delivered Volume <br /> Lateral 2 <br /> gal <br /> Lateral 3 <br /> Lateral 4 Maximum Delivered Volume <br /> Lateral 5 <br /> gal <br /> Lateral 6 <br /> 5. Additional Info for Type IV/Pretreatment Design <br /> A. Calculate the organic loading using option I or 2 <br /> 1. Organic Loading =Pounds of BOD X Units <br /> lbs/day X lbs BOD/day <br /> 2. Organic Loading to Pretreatment Unit =Design Flow X Estimated BOD in mg/L in the effluent X 8.35-1-1,000,000 <br /> gpd X mg/L X 8.35+1,000,000= lbs BOD/day <br /> B. Type of Pretreatment Unit Being Installed: <br /> C. Calculate Soil Treatment System Organic Loading: lbs.BOD/day Bottom Area =lbs/day/ft2 <br /> lbs/day= ft2= lbs/day/ft2 <br /> Comments/Special Design Considerations: <br /> I hereby certify that I have completed this work in accordance with all applicable ordinances,rules and laws. <br /> Joseph J Olson �� 810 02/04/14 <br /> (Designer) (Signature) (License#) (Date) <br />