Laserfiche WebLink
- OSTP Pressure Distribution <br /> UNIVERSITY ° <br /> Minnesota Pollution Design Worksheet OF MINNESOTA .., ," <br /> Control Agency �� <br /> 12. Select Type of Manifold Connection (End or Center): J' End ❑ Center <br /> 13. Select Lateral Diameter: 2.00 in Table H <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.170 Gallons/ft Pipe <br /> Pipe Liquid <br /> 15. Volume of Distribution Piping = Diameter Per Foot <br /> =[Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping (Line 14)] 1 0.045 <br /> 1.25 0.078 <br /> 3 X 61 ft X 0.170 gal/ft = 31.1 Gallons 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 31.1 gals X 4 = 124.4 Gallons 4 0.661 <br /> Cleanouts manifold pipe <br /> Manifold pipe 1 <br /> J pipe from pump <br /> J <br /> V dean outs et 2 <br /> .000.01.0000 t` <br /> _. ' Altemate locationLOP <br /> ` of pipe from pump 1 . <br /> • <br /> as <br /> alternate location <br /> %%------- Pipe from pump of pipe from pump <br />