My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00702 - septic new
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2360 Willow Hill Drive - 03-117-23-23-0023
>
Permits/Inspections
>
2014 - 00702 - septic new
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:43 PM
Creation date
2/13/2020 9:47:47 AM
Metadata
Fields
Template:
x Address Old
House Number
2360
Street Name
Willow Hill
Street Type
Drive
Address
2360 Willow Hill Dr
Document Type
Permits/Inspections
PIN
0311723230023
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. <br /> OSTP Basic Pump Selection Design UNIVERSITY <br /> Minnesota Pollution ,,. M :;, <br /> Worksheet OF MINNESOTA - <br /> Control Agency <br /> 1. PUMP CAPACITY Project ID: v 06.12.13 <br /> Pumping to Gravity or Pressure Distribution: i 0 Gravity b Pressure Selection required <br /> 1. If pumping to gravity enter the gallon per minute of the pump: GPM (10-45 gpm) <br /> 2. If pumping to a pressurized distribution system: 29.0 GPM <br /> 3. Enter pump description: <br /> 2. HEAD REQUIREMENTS s treatment system• <br /> Q point or discharge <br /> A. Elevation Difference 17 ft <br /> t"---, o+eneK4" <br /> between pump and point of discharge: ;-, _ <br /> Net pipeElevation <br /> B. Distribution Head Loss: 5 ft a S difference <br /> C. Additional Head Loss: ft(due to special equipment,etc.) - 7 • <br /> Table(.Friction Loss in Plastic Pipe per 100ft <br /> Distribution Head Loss <br /> -- <br /> Flow Rate Pipe Diameter(inches) <br /> Gravity Distribution = Oft <br /> (GPM) 1 1.25 1.5 I 2 <br /> Pressure Distribution based on Minimum Average Head 10 9.1 3.1 1.3 0.3 <br /> Value on Pressure Distribution Worksheet: 12 12.8 4.3 1.8 0.4 <br /> Minimum Average Head Distribution Head Loss 14 17.0 5.7 2.4 i 0.6 <br /> 1ft 5ft 16 21.8 7.3 3.0 0.7 <br /> 2ft bft 18 I 9.1 3.8 0.9 <br /> 5ft 10ft 20 I 11.1 4.6 1.1 <br /> 25 I 16.8 6.9 1.7 <br /> D. 1.Supply Pipe Diameter: 2.0 in 30 23.5 9.7 1 2.4 <br /> 35 12.9 3.2 <br /> 2.Supply Pipe Length: 75 ft 40 16.5 4.1 <br /> E. Friction Loss in Plastic Pipe per 100ft from Table I: 45 20.5 5.0 <br /> 50 6.1 <br /> Friction Loss= 2.23 ft per 100ft of pipe 55 7.3 <br /> 60 8.6 <br /> F. Determine Equivalent Pipe Length from pump discharge to soil dispersal area discharge 65 10.0 <br /> point. Estimate by adding 25%to supply pipe length for fitting loss. Supply Pipe Length <br /> 70 11.4 <br /> (D.2) X 1.25=Equivalent Pipe Length 75 I 13.0 <br /> 75 ft X 1.25 = 93.8 ft 85 16.4 <br /> 95 I 20.1 <br /> G. Calculate Supply Friction Loss by multiplying Friction Loss Per 100ft (Line E)by the Equivalent Pipe Length (Line F)and divide by 100. <br /> Supply Friction Loss= <br /> 2.23 ft per 100ft X 93.8 ft + 100 2.1 ft <br /> H. Total Head requirement is the sum of the Elevation Difference (Line A),the Distribution Head Loss(Line B),Additional Head Loss(Line C),and the <br /> Supply Friction Loss(Line G) <br /> 17.0 ft + 5.0 ft + ft + 2.1 ft = 24.1 ft <br /> 3. PUMP SELECTION <br /> A pump must be selected to deliver at least 29.0 GPM(Line 1 or Line 2)with at least 24.1 feet of total head. <br /> Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.