My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00702 - septic new
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2360 Willow Hill Drive - 03-117-23-23-0023
>
Permits/Inspections
>
2014 - 00702 - septic new
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:43 PM
Creation date
2/13/2020 9:47:47 AM
Metadata
Fields
Template:
x Address Old
House Number
2360
Street Name
Willow Hill
Street Type
Drive
Address
2360 Willow Hill Dr
Document Type
Permits/Inspections
PIN
0311723230023
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
View images
View plain text
OSTP Pressure Distribution >3 � <br /> ,... ;, aira <br /> Minnesota Pollution Design Worksheet UNIVERSITY <br /> Control Agency OF MINNESOTA <br /> Project ID: v 06.12.13 <br /> 1. Media Bed Width: 10 ft <br /> 2. Minimum Number of Laterals in system/zone= Rouded up number of [(Media Bed Width - 4) = 3] + 1. <br /> ( 10 -4 ) + 1 = 3 laterals Does not apply to at-grades <br /> 3. Designer Selected Number of Laterals: 3 laterals <br /> Cannot be less than line 2 (accept in at-grades) <br /> ,. <br /> 4. Select Perforation Spacing: 3.0 ft <br /> 5. Select Perforation Diameter Size: 7/32 in $8: k <br /> 6. Length of Laterals = Media Bed Length - 2 Feet. <br /> 63 - 2ft = 61 ft Perforation can not be closer then 1 foot from edge. <br /> 7 Determine the Number of Perforation Spaces. Divide the Length of Laterals by the Perforation Spacing <br /> and round down to the nearest whole number. <br /> Number of Perforation Spaces = 61 ft - 3 ft 20 Spaces <br /> Number of Perforations per Lateral is equal to 1.0 plus the Number of Perforation Spaces. Check table <br /> 8. below to verify the number of perforations per lateral guarantees less than a 10%discharge variation. The <br /> value is double with a center manifold. <br /> Perforations Per Lateral = 20 Spaces + 1 = 21 Perfs. Per Lateral <br /> Maximum Number of Perforations Per Lateral to Guarantee<10%Discharge Variation <br /> '!,Inch-Perforations 7132 Inch Perforations <br /> Pipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> Perforation Spacing(Feet) <br /> 1 1/ 11/2 2 3 (Feet) 1 114 11 2 3 <br /> 2 10 13 18 30 60 2 11 16 21 34 68 <br /> 21 8 12 16 28 54 21 10 14 20 32 64 <br /> 3 I $ 12 16 25 52 3 9 14 19 30 60 <br /> 3/16 Inch Perforations 1/8 Inch Perforations <br /> Pipe Diameter(Inches) Perforation Spacing Pipe Diameter(Inches) <br /> Perforation Spacing(Feet) I 114 11/2 2 3 (Feet) I 114 11/2 2 3 <br /> 2 12 18 26 46 87 2 21 33 44 74 149 <br /> 2/ 12 17 24 40 80 21/2 20 30 41 69 135 <br /> 3 12 16 22 37 75 3 20 29 38 64 128 <br /> 9. Total Number of Perforations equals the Number of Perforations per Lateral multiplied by the Number of <br /> Perforated Laterals. <br /> 21 Perf. Per Lat. X 3 Number of Perf. Lat. = 63 Total Number of Perf. <br /> 10. Select Type of Manifold Connection (End or Center): [] End ❑ Center <br /> 11. Select Lateral Diameter(See Table): 2.00 in <br />
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).