My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013 - 00685 - septic
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2325 Willow Hill Dr - 03-117-23-23-0022
>
Septic
>
2013 - 00685 - septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:35:40 PM
Creation date
2/13/2020 8:58:06 AM
Metadata
Fields
Template:
x Address Old
House Number
2325
Street Name
Willow Hill
Street Type
Drive
Address
2325 Willow Hill Dr
Document Type
Septic
PIN
0311723230022
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Design Summary Worksheet UNIVERSITY <br /> Minnesota Pollution OF MINNESOTA <br /> Control Agency _--- --,�N`•�- <br /> v 11.05.31 <br /> Property Owner/Client: Arthur J. Nelson Estate <br /> Site Address: Proposed lot 1, Orono, MN 55356 Site A <br /> 1. AVERAGE DESIGN FLOW: <br /> A. Design Flow: 750 Gallons Per Day(GPD) Note: The estimated design flow is considered a peak flow rate including a safety <br /> factor.For long term performance, the average daily flow is recommended to be< <br /> B. Septic Tank capacity: 2250 Gallons 60%of this value. <br /> C. Number of Septic Tanks or Compartments: 2 Effluent Screen Et Alarm? Yes <br /> Type of Soil Treatment and Dispersal Area* Type of Distribution* <br /> 0 Trenches 0 Bed Q Mound C At-Grade 0 Gravity Distribution ®Pressure Distribution-Level 0 Pressure Distribution-Unlevel <br /> 0 Dnp Distribution 0 None-Holding Tanks Only <br /> *Selection Required Benchmark Elev= 100 ft <br /> System Type Benchmark Location: Test hole# 1 <br /> Iii Type I Type II I-1,Type III I Type IV Type V Type of Distribution Media: <br /> Rock <br /> D. Pump Tank 1 Capacity: Gallons Pump Tank 2 Capacity: Gallons <br /> 2. SITE EVALUATION: <br /> A. Depth to Limiting Layer: 28 inches 2.3 ft Elevation of Limiting Layer: 97.7 ft <br /> B. Measured Percent Land Slope: 4.0 % 0.0 <br /> C. Soil Texture: Loam Percolation Rate: 6 Minutes per Inch <br /> D. Soil Hydraulic Loading Rate: 0.60 GPD/ft2 E. Contour Loading Rate 12.0 Gat/ft <br /> 3. DESIGN SUMMARY <br /> Trench Design Summary <br /> Absorption Area ft2 Sidewall Depth in Trench Width in <br /> Total Lineal Feet ft Number of Trenches Maximum Trench Depth in <br /> Designers Max Trench Depth in <br /> Bed Design Summary <br /> Absorption Area ft2 Media Below Pipe in Bed Length ft <br /> Bed Width ft Maximum Bed Depth in Designer's Max Bed Depth in <br /> Mound Design Summary <br /> Absorption Area 625 ft2 Bed Length 63 ft Bed Width <br /> 10.0 ft <br /> Absorption Width 20.0 ft Clean Sand Lift 1.0 ft Berm Width (slope 0-1%) ft <br /> Upslope Berm Width 10.4 ft Downslope Berm Width 16.2 ft Endslope Berm Width 10.2 ft <br /> Total System Length 83 ft Total System Width 37 ft <br /> At-Grade Design Summary <br /> Absorption Bed Width ft Absorption Bed Length ft System Height ft <br /> Absorption Bed Area ft2 Upslope Berm Width ft Downslope Berm Width ft <br /> f I_ .. . . .. I I. .. . ... ... I I.. <br />
The URL can be used to link to this page
Your browser does not support the video tag.