Laserfiche WebLink
OSTP Pressure Distribution }_, ,1� <br /> UNIVERSITY <br /> Minnesota Pollution Design Worksheet OF MINNESOTA <br /> Control Agency ,-A�_; <br /> 12. Select Type of Manifold Connection (End or Center): End ❑ Center <br /> 13. Select Lateral Diameter: 2.00 in Table II <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.170 Gallons/ft Pipe <br /> Pipe Liquid <br /> 15. Volume of Distribution Piping = Diameter Per Foot <br /> = [Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping (Line 14)] 1 0.045 <br /> 1.25 0.078 <br /> 3 x 61 ft X 0.170 gal/ft = 31.1 Gallons 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 31.1 gals X 4 = 124.4 Gallons 4 0.661 <br /> - Cleanouts - - - -_ _ manifold pipe` <br /> J - w `I <br /> i' Manifold pipe, 1 i <br /> I I _ `� pipe from pump <br /> ' clean outs <br /> `.". ' Alternate location <br /> of pipe from pump 1- <br /> alternate location <br /> Pipe from pump V of pipe from pump <br />