Laserfiche WebLink
OSTP Pressure Distribution <br /> UNIVERSITY <br /> Minnesota Pollution <br /> Control Agency Design Worksheet OF MINNESOTA '="'-- ,,,-' <br /> 12. Select Type of Manifold Connection (End or Center): 1 End [1 Center <br /> 13. Select Lateral Diameter: 2.00 in Table II <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.170 Gallons/ft Pipe <br /> 15. Volume of Distribution Piping = Pipe Liquid <br /> Diameter Per Foot <br /> = [Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 14)] 1 0.045 <br /> 3 X 61 ft X 0.170 gal/ft = 31.1 Gallons 1.25 0.078 <br /> 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 31.1 gals X 4 = 124.4 Gallons 4 0.661 <br /> _- Cleanouts --" - -- __ manifold pipe` <br /> I <br /> Manifold pipes 1 �` i <br /> wir�% J pipe from pump <br /> =lean outs a `� <br /> �.� Alternate location t <br /> of pipe from pump � 0 <br /> alternate location <br /> Pipe from pump of pipe from pump <br />