2013 - Soil & Percolation Testing
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2300 Willow Hill Dr - 03-117-23-32-0026
>
Septic
>
2013 - Soil & Percolation Testing
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:49 PM
Creation date
2/12/2020 1:38:38 PM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
Willow Hill
Street Type
Drive
Address
2300 Willow Hill Dr
Document Type
Septic
PIN
0311723320026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> • <br /> OSTP Mound Design Worksheet <br /> UNIVERSITY -fit <br /> Minnesota Pollution 0 <br /> Control Agency >1 / Slope OF MINNESOTA ~vA'� <br /> 1. SYSTEM SIZING: Project ID: v 12.08.06 <br /> A. Design Flow: 750 GPD TABLE IXa <br /> B. Soil Loading Rate: 0.60 GPD/ft2 LOADING RATES FOR DETERMINING BOTTOM ABSORPTION AREA <br /> AND ABSORPTION RATIOS USING PERCOLATION TESTS <br /> C. Depth to Limiting Condition: 1.3 ft I Treatment Level C Treatment Level A,A-2,B, <br /> D. Percent Land Slope: 7.0 % f Percolation Rate absorption around resorption around <br /> Area Loading Area Loading <br /> (MPI) Rate Absorption Rate Absorption <br /> E. Design Media Loading Rate: 1.2 GPD/ft2 ; (gpd/tt') Ratio (gpd/ft') Ratio <br /> I <br /> F. Mound Absorption Ratio(Table IXa): 2.00 >01 - 1 - 1 <br /> G.Design Contour Loading Rate: 12.0 GPD/ft 101 to 5 1.2 1 1.6 1 <br /> 10 1 to 5(fine sand 0-6 2 1 1.6 <br /> Table I land loamy fore sandl <br /> MOUND CONTOUR LOADING RATES: ;610 15 0.78 1.5 1 1.6 <br /> moasured ' Toxturo-dorivod Contour 16 to 30 0.6 2 0.78 2 <br /> Poi c Rate OR mound absorption ratio Loading 131 to 45 0.5 2.4 0.78 2 <br /> Raton <br /> 146 t0 60 0.45 2.6 0.6 2.6 <br /> -6ompi 1.0, 1.3.2.0.2.4.2.6 • 112 <br /> 1,61 to 120 - 5 0.3 5.3 <br /> 61-120 mpi CR 5.0 • cl2 1>120 - - - <br /> x 120 ntpi' .'5.0' -6' 'Systems with these values are not Type I systems. Contour Loading Rate(linear <br /> loading rate)is a recommended value. <br /> 2. DISPERSAL MEDIA SIZING <br /> A. Calculate Required Dispersal Bed Area:Design Flow (1.A):Design Media Loading Rate (1.E)=ft2 <br /> If a larger dispersal media area 750 GPD: 1.20 GPD/ft2 = 625 ft2 <br /> is desired,enter size: ft2 <br /> B. Calculate Dispersal Bed Width:Contour Loading Rate (1.G):Design Media Loading Rate (1.E)=Bed Width <br /> 12.0 ft . 1.2 gpd/ft2 = 10 ft <br /> C. Calculate Dispersal Bed Length: Dispersal Bed Area (2.A)=Bed Width (2.B)=Bed Length <br /> 625 ft2 : 10 ft = 63 ft <br /> D. Enter Dispersal Media: <br /> E. If using a registered product,enter the Component Length: in: 12 = ft <br /> F. If using a registered product,enter the Component Width: in: 12 = ft <br /> G. Number of Components per Row =Bed Length (2.C)divided by Component Length (4.J) (Round up) <br /> ft : ft= components/row <br /> H. Number of Rows =Bed Width (2.B)divided by Component Width (4.K) (Round up) <br /> Adjust Contour Loading Rate on Design Summary page until this number is a whole number. Note:CLR of 10.8 gal/ft results in 9 foot wide bed. <br /> ft: ft= rows <br /> I. Total Number of Components =Number of Components per Row X Number of Rows <br /> X = components <br />
The URL can be used to link to this page
Your browser does not support the video tag.