Laserfiche WebLink
OSTP Pressure Distribution <br /> UNIVERSITY ' , y <br /> Minnesota Pollution Design Worksheet � <br /> OF MINNESOTA <br /> Control Agency <br /> ��a <br /> 12. Select Type of Manifold Connection (End or Center): [ End 7 Center <br /> 13. Select Lateral Diameter: 2.00 in Table Il <br /> Volume of Liquid in <br /> 14. Volume of Liquid Per Foot of Distribution Piping: 0.170 Gallons/ft Pipe <br /> Pipe Liquid <br /> 15. Volume of Distribution Piping = <br /> Diameter Per Foot <br /> = [Number of Perforated Laterals (Line 1)X Length of Laterals (Line 4)X (inches) (Gallons) <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 14)] 1 0.045 <br /> 1.25 0.078 <br /> 3 X 61 ft X 0.170 gal/ft = 31.1 Gallons 1.5 0.110 <br /> 16. Minimum Dose=Volume of Distribution Piping(Line 15)X 4 2 0.170 <br /> 3 0.380 <br /> 31.1 gals X 4 = 124.4 Gallons 4 0.661 <br /> Cleanouts -_ manifold pipe s <br /> III/ f 2. <br /> /� Manifold pipe <br /> .001 � pipe from pump <br /> o.. :lean outs a .1 ` <br /> _..�� Alternate locationiii1.00 <br /> �. ` of pipe from pump alternate <br /> nate location <br /> Pipe from pump LIO. of pipe from pump <br />