Template:
x Address Old
House Number
2300
Street Name
Willow Hill
Street Type
Drive
Address
2300 Willow Hill Dr
Document Type
Septic
PIN
0311723320026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Mound Design Worksheet , z <br /> Minnesota Pollution p UNIVERSITY 4`` <br /> 1% Slope OF MINNESOTA <br /> Control Agency `�� <br /> 1. SYSTEM SIZING: Project ID: v 12.08.06 <br /> A.Design Flow: 750 GPD TABLE IXa <br /> B. Soil Loading Rate: 0.60 GPD/ft2 'LOADING RATES FOR DETERMINING BOTTOM ADSORPTION AREA <br /> AND ABSORPTION RATIOS USING PERCOLATION TESTS <br /> C.Depth to Limiting Condition: 1.7 ft Treatment Level C Treatment Levet A,A-2,e, <br /> D.Percent Land Slope: 7.0 Percolation Rate Absorption Mound Absorption hound <br /> % I, Area i.0adin; Area Loading <br /> E►+P11 Rate Absorption Rate Absorption <br /> i E. Design Media Loading Rote: 1.2 GPD/ft2 (rmd `) Ratio (gPdne) Ratio <br /> F.Mound Absorption Ratio(Table IXa): 2.00 j<01 - 1 - 1 <br /> G.Design Contour Loading Rate: 12.0 GPD/ft 0 1 to 5 1.2 1 1.6 1 <br /> 0.1 to 5(fine.sand 0.6 2 1 1.6 <br /> Table I land loamy fine sand) <br /> MOUND CONTOUR LOADING RATES: 116 to 15 0.78 1.5 1 1.6 <br /> Moasurod Texture-dor-Nod od Contour 16 to 30 0.6 2 0.78 2 <br /> 9.81K Rate OR mound absorption ratio Loadie;ng 31 to 45 0.5 2.4 0.78 2 <br /> Rat <br /> 146 to 60 0.45 2.6 0.8 2.6 <br /> s 60ntpi 1.0,1.3,2.0.2.4,2.6 • s12 <br /> i61 to 120 - 5 0.3 5.3 <br /> 61.120mpi OR 5.0 • :12 1>120 - - - - <br /> 120 mpi' .5.0' • _6" "Systems with these values are not Type I systems. Contour Loading Rate(linear <br /> loading rate)is a recommended value. <br /> 2. DISPERSAL MEDIA SIZING <br /> A. Calculate Required Dispersal Bed Area:Design Flow (1.A):Design Media Loading Rate (1.E)=ft2 <br /> If a larger dispersal media area 750 GPD= 1.20 GPD/ft2 = 625 ft2 <br /> is desired,enter size: ft2 <br /> B. Calculate Dispersal Bed Width:Contour Loading Rate (1.G)=Design Media Loading Rate (1.E)=Bed Width <br /> 12.0 ft = 1.2 gpd/ft2 = 10 ft <br /> C. Calculate Dispersal Bed Length: Dispersal Bed Area (2.A)+Bed Width (2.B)=Bed Length <br /> 625 ft2 : 10 ft = 63 ft <br /> D. Enter Dispersal Media: <br /> E. If using a registered product,enter the Component Length: in+ 12 = ft <br /> F. If using a registered product,enter the Component Width: in 6 12 = ft <br /> G.Number of Components per Row =Bed Length (2.C)divided by Component Length (4.J) (Round up) <br /> ft a ft= components/row <br /> H. Number of Rows =Bed Width (2.B)divided by Component Width (4.K)(Round up) <br /> Adjust Contour Loading Rate on Design Summary page until this number is a whole number. Note:CLR of 10.8 gal/ft results in 9 foot wide bed. <br /> ft= ft= rows <br /> I. Total Number of Components =Number of Components per Row X Number of Rows <br /> X = components <br />