My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00698 - septic system
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2300 Willow Hill Drive - 03-117-23-32-0026
>
Septic
>
2014 - 00698 - septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:49 PM
Creation date
2/12/2020 1:08:43 PM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
Willow Hill
Street Type
Drive
Address
2300 Willow Hill Dr
Document Type
Septic
PIN
0311723320026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pump Tank Sizing, Dosing and Float <br /> UNIVERSI <br /> and Timer SettingDesign Worksheet OF MINNESOTA <br /> 1TIMER or DEMAND FLOAT SETTINGS <br /> Select Timer or Demand Dosing: 0 Timer QQ Demand Dose <br /> A. Timer Settings <br /> 11. Required Flow Rate: <br /> A. From Design(Line 12 of Pressure Distribution or Line 10 of Non-Level'): GPM Note: This value must be <br /> adjusted after field <br /> B. Or calculated:GPM=Change in Depth(in)x Gallons Per Inch/Time Interval in Minutes <br /> measurement& <br /> in X gal/in: min= GPM calculation. <br /> 12. Flow Rate from Line 11.A or 11.B above. GPM <br /> 13.Calculate TIMER ON setting: <br /> Total Dosing Volume/GPM <br /> gal+ gpm= Minutes ON <br /> 14.Calculate TIMER OFF setting: <br /> Minutes Per Day(1440)/Doses Per Day- Minutes On <br /> 1440 min - doses/day - min = Minutes OFF <br /> 15. Pump Off Float-Measuring from bottom of tank: <br /> Distance to set Pump Off Float=Gallons to Cover Pump /Gallons Per Inch: <br /> gal+ gal/in= Inches <br /> 16. Alarm Float-Measuring from bottom of tank: <br /> Distance to set Alarm Float=Tank Depth(4A)X 90%of Tank Depth <br /> in X 0.90= in <br /> B. DEMAND DOSE FLOAT SETTINGS <br /> 17. Calculate Float Separation Distance using Dosing Volume. <br /> Total Dosing Volume/Gallons Per Inch <br /> 204 gal_ 25.5 gal/in= 8.0 Inches <br /> 18. Measuring from bottom of tank: <br /> A. Distance to set Pump Off Float=Pump and block height+2 inches <br /> 16 in+ 2 in = 18 Inches <br /> B. Distance to set Pump On Float=Distance to Set Pump-Off Float +Float Separation Distance <br /> 18 in+ 8.0 in = 26 Inches <br /> C. Distance to set Alarm Float=Distance to set Pump-On Float +Alarm Depth (2-3 inches) <br /> 26 in+ 2.0 in= 28 Inches <br /> FLOAT SETTINGS <br /> DEMAND DOSING TIMED DOSING <br /> Alarm Depth 28 in Alarm Depth in <br /> Pump On 26 in 51 Gal . <br /> Pump Off 18 in 204 Gal Pump Off in <br /> 458.82 Gal <br /> I—I I—I <br />
The URL can be used to link to this page
Your browser does not support the video tag.