My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00698 - septic system
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2300 Willow Hill Drive - 03-117-23-32-0026
>
Septic
>
2014 - 00698 - septic system
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:49 PM
Creation date
2/12/2020 1:08:43 PM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
Willow Hill
Street Type
Drive
Address
2300 Willow Hill Dr
Document Type
Septic
PIN
0311723320026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pressure Distribution Y, <br /> UNIVERSITY p <br /> Minnesota Pollution Design Worksheet OF MINNESOTA <br /> Control Agency "L\---- <br /> 12. Calculate the Square Feet per Perforation. Recommended value is 4-11 ft 2 per perforation. Perforation Discharge(GPM) <br /> Does not apply to At-Grades <br /> a. Bed Area = Bed Width(ft)X Bed Length (ft) Perforation Diameter <br /> Head(ft) 3/E ,/16 7 <br /> /33 /4 <br /> 10 ft X 63 ft = 630 ft2 <br /> i.0' 0.18 0.41 0.56 0.74 <br /> b. Square Foot per Perforation =Bed Area divided by the Total Number of Perforations (Line 9). <br /> 1.5 0.22 0.51 0.69 0.9 <br /> 630 ft2 - 63 perforations = 10.0 ft2/perforations 2.0b 0.26 0.59 0.80 1.04 <br /> 2.5 0.29 0.65 0.89 1.17 <br /> 13. Select Minimum Average Head: 1.0 ft 3.0 0.32 0.72 0.98 1.28 <br /> • 4.0 0.37 0.83 1.13 1.47 <br /> 14. Select Perforation Discharge (GPM)based on Table: 0.56 GPM per Perforation 5.0` 0.41 0.93 1.26 1.65 <br /> 1 foot Dwellings with 3/16 inch to 1/4 inch <br /> 15. Determine required Flow Rate by multiplying the Total Number of Perforations by the perforations <br /> Perforation Discharge. Dwellings with 1/8 inch perforations <br /> 63 Perfs X 0.56 GPM per Perforation= 36 GPM 2 feet Other establishments and MSTS with 3/16 <br /> inch to 1/4 inch perforations <br /> 16. Volume of Liquid Per Foot of Distribution Piping(Table II): 0.170 Gallons/ft 5fee Other establishments and MSTS with 1/8 inch <br /> perforations <br /> 17. Volume of Distribution Piping = - <br /> Tablelf <br /> = [Number of Perforated Laterals (Line 3)X Length of Laterals (Line 6)X Volume of Liquid in <br /> (Volume of Liquid Per Foot of Distribution Piping(Line 16)] Pipe <br /> 3 X 61 ft X 0.170 gal/ft = 31.1 Gallons Pipe Liquid <br /> Diameter Per Foot <br /> 18. Minimum Dose=Volume of Distribution Piping(Line 17)X 4 (inches) (Gallons) <br /> 1 0.045 <br /> 31.1 gals X 4 = 124.4 Gallons <br /> 1.25 0.078 <br /> 1.5 0.110 <br /> manifold pipe, 2 0.170 <br /> 3 0.380 <br /> .. i 4 0.661 <br /> pipe from pump _-- _ <br /> 1... <br /> ` Cleanouts - <br /> • J <br /> dean outs - • - <br /> Manifold pipe , <br /> alternate location / "��' J <br /> of pipe from pump <br /> `,,.� Alternate location <br /> ` of pipe from pump <br /> `� Pipe from pump <br /> Comments/Special Design Considerations: <br />
The URL can be used to link to this page
Your browser does not support the video tag.