My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013 - 01184 - new structure
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2300 Willow Hill Drive - 03-117-23-32-0026
>
Permits/Inspections
>
2013 - 01184 - new structure
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:48 PM
Creation date
2/12/2020 12:51:02 PM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
Willow Hill
Street Type
Drive
Address
2300 Willow Hill Dr
Document Type
Permits/Inspections
PIN
0311723320026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
New Construction Energy Code Compliance Certificate <br /> Per NI 101.8 Building Certificate.A building certificate shall be posted in a permanently visible location inside hDate Certificate Posted <br /> building. The certificate shall be completed by the builder and shall list information and values of components <br /> fisted in Table NI 101.8. Place your <br /> Mailing Address of the Dwelling or Dwelling Unit City <br /> logo here <br /> ORONO <br /> Name of Residential Contractor MN License Number <br /> HENDEL HOMES <br /> THERMAL ENVELOPE RADON SYSTEM <br /> Type:Check All That Apply Passive Wo Fan) <br /> o <br /> Active(With fan and monometer or <br /> other.nysiem monitoring device) <br /> o a. 3 z U o b <br /> a o t a, <br /> d W oa a <br /> Insulation Location ° Z <br /> 3 o o EP ^e a��i o - <br /> c m 2 EFib c <br /> i <br /> I- Z w w w° w° u rx Other Please Describe Here <br /> Below Entire Slab <br /> Foundation Wall Type in location:interior exterior or integral <br /> Perimeter of Slab on Grade <br /> Rim Joist(Foundation) Type in location:interior exterior or integral <br /> Rim Joist(1st Floor+) Type in location:Interior exterior or Integral 1 <br /> Wall <br /> Ceiling,flat <br /> Ceiling,vaulted <br /> Bay Windows or cantilevered areas <br /> Bonus room over garage <br /> Describe other insulated areas <br /> Windows&Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor excludes skylights and one door)U: Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): R-value <br /> MECHANICAL SYSTEMS l Make-up Air Select a Type <br /> Appliances Heating System Domestic Water Heater Cooling System X Not required per mech.code <br /> Fuel Type NATURAUELECTRIC ELECTRIC Passive <br /> Manufacturer WATERFURNACE WATERFURNACE Powered <br /> Interlocked with exhaust device. <br /> Model NDV072 NDV072 Describe: <br /> Input in 199,000 Capacity in Output in 6 TON Other,describe: <br /> Rating or Size BTUS: Gallons: Tons: <br /> Heat Loss: 139,900 Heat Gain: Location of duct or system: <br /> Structure's Calculated <br /> AFUE or 96% SEER: 13 <br /> HSPF% <br /> Calculated 69,800 <br /> Efficiency cooling load: Cfm's <br /> "round duct OR <br /> Mechanical Ventilation System "metal duct <br /> Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): Not required per mech.code <br /> Select Type X Passive <br /> X Heat Recover Ventilator(HRV) Capacity in cfms: Low: 60 High: 300 Other,describe: <br /> Energy Recover Ventilator(ERV)Capacity in cfms: _Low: High: Location of duct or system: <br /> Continuous exhausting fan(s)rated capacity in cfms: 6"' FLEX M ECH ROOM <br /> Location of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in cfms: 108 6" FLEX <br /> Total ventilation(intermittent+continuous)rate in cfms: 215 "metal duct <br /> Cioutod by RAM vurdon 062009 <br />
The URL can be used to link to this page
Your browser does not support the video tag.