My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014 - 00083 - mechanical
Orono
>
Property Files
>
Street Address
>
W
>
Willow Hill Drive
>
2300 Willow Hill Drive - 03-117-23-32-0026
>
Permits/Inspections
>
2014 - 00083 - mechanical
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:36:49 PM
Creation date
2/12/2020 12:46:37 PM
Metadata
Fields
Template:
x Address Old
House Number
2300
Street Name
Willow Hill
Street Type
Drive
Address
2300 Willow Hill Dr
Document Type
Permits/Inspections
PIN
0311723320026
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�i Q 11111161601'inili^ni �VV /0 - 3/ - % <br /> V Date: / <br /> HEATING , COOLING & RADIANT • . <br /> Page: of <br /> 16411 Aberdeen St NE• Ham Lake, MN 55304(763) 434-7747c• <br /> ¢-rICJ— <br /> � <br /> 2795 Highway 55 East • Eagan, MN 55121 (651)452-2025 Project: .5Xek- % es_____-=-_ , ' <br /> www.airmechanicalinc.com <br /> Ventilation, Makeup and Combustion Air Calculations <br /> Submittal Form For New Dwellings <br /> These blank submittal forms and instructions are available at the City of Chanhassen website and at City Hall. The completed form must be submit- <br /> ted in duplicate at the time of application of a mechanical permit for new construction. Additional forms may be downloaded and printed at: <br /> http://www.ci.chanhassen.mn.us/servibuild.html. <br /> Site address D AO Date <br /> Contractor Mlidd <br /> / %fie 3 Completed Al i . _.(1 �, <br /> Section A ���'I <br /> Ventilation Quantity <br /> (Determine quantity by using Table N1104.2 or Equation 11-1) <br /> Square feet(Conditioned area including 7 7 J <br /> Basement-finished or unfinished) /I `�� Total required ventilation . <br /> Number of bedrooms 4/ Continuous ventilation f C3 Y <br /> Directions-Determine the total and continuous ventilation rate by either using Table N1104.2 or equation 11-1. <br /> The table and equation are below. <br /> 3 Table N1104.2 <br /> Total and Continuous Ventilation Rates(in cfm) <br /> Number of Bedrooms <br /> 1 2 3 4 5 6 <br /> Conditioned space(in Total/ Total/ Total/ Total/ Total/ Total/ <br /> sq.ft.) continuous continuous continuous continuous continuous continuous <br /> 1000-1500 60/40 75/40 90/45 105/53 120/60 135/68 <br /> 1501-2000 70/40 85/43 100/50 115/58 130/65 145/73 <br /> 2001-2500 80/40 95/48 110/55 125/63 140/70 155/78 <br /> 2501-3000 90/45 105/53 120/60 135/68 150/75 165/83 <br /> 3001-3500 100/50 115/58 130/65 145/73 160/80 175/88 <br /> 3501-4000 110/55 125/63 140/70 155/78 170/85 185/93 <br /> 4001-4500 120/60 135/68 150/75 165/83 180/90 195/98 <br /> 4501-5000 130/65 145/73 160/80 175/88 `190/95 205/103 <br /> 5001-5500 140/70 155/78 170/85 185/93 200/100 215/108 <br /> 5501-6000 150/75 165/83 180/90 195/98 210/105 225/113 <br /> • ati•• <br /> (6.62 x square feet of conditioned space)+[15 x(number of bedrooms+1)1=Total ventilation rate(cfm) ` <br /> Total ventilation-The mechanical ventilation system shall provide sufficient outdoor air to equal the total ventilation rate average, <br /> for each one-hour period according to the above table or equation. For heat recovery ventilators(HRV)and energy recovery ventila- <br /> tors(ERV)the average hourly ventilation capacity must be determined in consideration of any reduction of exhaust or out outdoor <br /> air intake,or both,for defrost or other equipment cycling. <br /> Continuous ventilation-A minimum of 50 percent of the total ventilation rate,but not less than 40 cfm,shall be provided,on a con- <br /> tinuous rate average for each one-hour period. The portion of the mechanical ventilation system intended to be continuous may <br /> have automatic cycling controls providing the average flow rate for each hour is met. <br /> G:ISAFETYI,JK\Vent-makeup-comb air submittal(2).docx Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.