2011 - 00888 - new septic
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
1125 Willow Drive North - 28-118-23-41-0002
>
Septic
>
2011 - 00888 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:24:46 PM
Creation date
2/12/2020 9:13:48 AM
Metadata
Fields
Template:
x Address Old
House Number
1125
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
1125 Willow Drive North
Document Type
Septic
PIN
2811823410002
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OSTP Pump Selection Design UNIVERSITY ; <br /> Minnesota Pollution Worksheet OF MINNESOTA . :,--''- '1'..,:f-:.:-. <br /> tib. <br /> Control Agency <br /> 1. PUMP CAPACITY <br /> A. Pumping to Gravity or Pressure Distribution: 0 Gravity OO Pressure <br /> 1. If pumping to gravity enter the gallon per minute of the pump: GPM <br /> 2. If pumping to pressure, is the pump for the treatment system or the collection system: <br /> Treatment System 0 Collection System <br /> 3. If pumping to a pressurized treatment system,what part or type of system: <br /> 0 Soil Treatment Unit ❑Media Filter ❑Other <br /> 4. If pumping to a pressurized distribution system: 38.0 GPM <br /> (Line 11 of Pressure Distribution or Line 10 of Non-Level or enter if Collection System) <br /> 2. HEAD REQUIREMENTS <br /> -Soil treatment system <br /> 3. Elevation Difference 9 ft &point of discharge <br /> between pump and point of discharge: <br /> or <br /> NOTE:IF system is an individual subsurface sewage treatmentpvtmeten <br /> system,complete steps 4 9. If system is a Collection System, nlet pipe Iiinevation ....... <br /> • <br /> skip steps 4, 5, 7 and 8 and go to Step 10. x difference <br /> 4. Distribution Head Loss: 5 ft <br /> 5. Additional Head Loss: ft(due to special equipment,etc.) <br /> Distribution Head Loss Friction Loss in Plastic Pipe per 100 ft <br /> Gravity Distribution = Oft (C=130) <br /> Nominal Pipe Diameter <br /> Pressure Distribution based on Minimum Average Head Flow Rate <br /> Value on Pressure Distribution worksheet: 2 3 <br /> (GPM) 1 1' 11/4 <br /> Minimum Average Head Distribution Head Loss 10 9.11 3.08 1.27 0.31 -- <br /> 1 ft 5ft 12 12.77 4.31 1.78 0.44 <br /> 2ft 6ft <br /> 5ft 10ft 14 16.99 5.74 2.36 0.58 -- <br /> 16 --- 7.35 3.03 0.75 0.10 <br /> 6. A. Supply Pipe Diameter: 2.0 in 18 --- 9.14 3.76 0.93 0.13 <br /> B.Supply Pipe Length: 140 ft 20 --- 11.11 4.58 1.13 0.16 <br /> 25 --- 16.79 6.92 1.71 0.24 <br /> 7. Based on Friction Loss in Plastic Pipe per 100ft from Table I: 30 9.69 2.39 0.33 <br /> Friction Loss= 3.67 ft per 100ft of pipe 35 12.90 3.18 0.44 <br /> 40 --- --- 16.52 4.07 0.57 <br /> 8. Determine Equivalent Pipe Length from pump discharge to soil dispersal 45 --- --- --- 5,07 0.70 <br /> area discharge point. Estimate by adding 25%to supply pipe length for <br /> fitting loss. Supply Pipe Length(5.B) X 1.25=Equivalent Pipe Length 50 6.16 0.86 <br /> 55 --- --- --- 7.35 1.02 <br /> 140 ft X 1.25 = 175.0 ft 60 --- --- --- 8.63 1.20 <br /> 9. Calculate Supply Friction Loss by multiplying Friction Loss Per 100ft (Line 6)by 1 65 10.01 1.39 <br /> Supply Friction Loss= 70 --- --- --- 11.48 1.60 <br /> 3.67 ft per 100ft X 175.0 ft - 100 = 6.4 ft <br />
The URL can be used to link to this page
Your browser does not support the video tag.