My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008 - 00069 - new septic
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
1020 Willow Dr N - 27-118-23-32-0022
>
Septic
>
2008 - 00069 - new septic
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:20:38 PM
Creation date
2/12/2020 9:03:15 AM
Metadata
Fields
Template:
x Address Old
House Number
1020
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
1020 Willow Drive North
Document Type
Septic
PIN
2711823320022
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
C AY.-- <br /> Koch ' s Soil Testing <br /> • <br /> Box 81 <br /> Loretto, Minn., 55357 <br /> Jim Cox 9/3/07 <br /> 1020 Willow Dr. <br /> Orono, Minn. <br /> Tel 952-473-9625 <br /> Job Site; Above Address <br /> The present drainfield was determine by the City of Orono to be a <br /> failing system and has to be replaced. <br /> * See City of Orono f information for the details. <br /> The site that was tested had an average percolation rate of 11 . 1 min/in. <br /> and the depth to mottled soil was at 1 . 5-1 . 8 ft. , with standing <br /> water at 1 . 7-2. 0 ft. <br /> The current City of Orono Codes require that the minnimum depth to <br /> mottled soil and standing water musr be at 48 inches or deeper before <br /> a trench drainfield system can be installed. <br /> Therefore with the above information the only type of system that <br /> can be installed is a pressurized mound system and still be consider <br /> a standard drainfield system according th- to the current codes. <br /> The size of mound system needed for a 3 bedroom home would <br /> be the following size; <br /> Sizing Factors; PercolatiorrRate Range 46-60 min/in ( Clay Loam Soil ) <br /> Daily-Water Use; ; --450 gal/day • <br /> Land Slope; ;--2 % <br /> Overall.'Size of mound needed; ;--2952 sq. ft. <br /> Upslope Length--69 ft. <br /> Downslope LLedgth---75 ft. <br /> Width; ;--41 ft. ( Upslope--14 ft. , Rock--loft. --17 f <br /> Absorption Width--27 ft. ) <br /> Rock Bed Size; ; -410 sq. ft. ( Width--10 ft. , Length--41 ft. ) <br /> `11"L'Amti int of materials needed; <br /> Sand--160 yds. , 224 yds. Ave. Depth--1 . 6 ft. <br /> Rock; --16 ydsd. 23 tons " "--1 . 0, ft <br /> Sandy Loam--35 yds. " " 1 . 0 ft. <br /> Topsoil--120 yds. "-- 9-12 inches <br /> * The above amounts could vary by 10 % plus or minus. <br /> This mound must 'be. pressurized therefore a pump tank and a pump <br /> is needed; <br /> Size of pump tank; ; 1 -1000 gallon sealed tank <br /> Size of pump; ; 30 g.p.m. ( must overcome at least 14. 9 ft. of hedd press. ) <br /> Pumping Rate; ; 139 gal/cycle ( 4 cycles/day ) <br /> * An alarm system must be installed to indicate pump failure, this <br /> must be both a sound and a light alarm system. <br /> Size of Septic Tanks needed; ; 2-1000 gallon seasled septic tanks, <br /> these tanks should be pumped out every 2-3 years. <br /> Robert A. Koch 2 f�_ n.G M. P. C. A. Cert . a 193/ 1429 <br />
The URL can be used to link to this page
Your browser does not support the video tag.