Laserfiche WebLink
POOL KIT MATERIAL LIST <br /> I <br /> a <br /> ADJUSTABLE w z a <br /> A-FRAME RECTANGULAR 18 x 36 z w W LL ¢ x p z <br /> �'• FILLER a -IzW JJJJJJ U- ZF. <br /> RECTANGLE 5Zaazzzzzz aw -/ a O <br /> + uViawzaaaaaaaa � -a 1- <br /> SPACER o -_—, 2 zzzgaNQmul � . <br /> a 1-- a a agaaa � Do °6 = a ¢ <br /> RADIUS / avYi ¢ aaaaJo Jo LL ,vQ ¢ � Q � z <br /> + % FILLER SIZE 63 Co Co min c CI iv ¢ ¢ Q 0 z cc cn <br /> 6° MIN. rIS x 36 9 1 2 2 2 124 4 I I I I <br /> CON RS.I. 18 x 36 w/ctr.stairs 7 1 2 2 2 I 12 4 4 I I I I <br /> t FOOOOTINGTINGET TYPICAL CORNER I$x 36 w/side stairs 7 1 2 1 2 3 13 4 4 1 1 1 1 <br /> F <br /> —I. <br /> NOTES <br /> 1.POOL IS DESIGNED FOR USE BELOW GRADE AND <br /> - *Ir ``r <br /> = *' ONLY IN AREAS MIN '6 THE GROUNDWATER`,r ` FINISHED GRADE.OF WHERE BELOW THE PROPOSED <br /> F- 2'6° OVERDIG 1 <br /> 8, 2.BACKFILL WITH CLEAN EARTH,FREE OF ROOTS <br /> - - <br /> AND DEBRIS.DO NOT ALLOW THE HEIGHT OF <br /> STEP BACKFILL TO EXCEED THE HEIGHT OF THE <br /> 6 — UNIT —' 2 WATER IN THE POOL BY MORE THAN 6',NOR <br /> I —., WATER TO EXCEED BACKFILL BY MORE THAN 6". <br /> 4 8 8 83. POUR 2500 P.S.I.CONCRETE FOOTING AROUND <br /> 8 ENTIRE PERIMETER,MIN.6'DEEP. <br /> T T T T - 4.3'WIDE CONCRETE DECK IS TO BE POURED AT <br /> I LEAST 3'THICKNESS AND A SLOPE OF 114"TO 1' <br /> I I AWAY FROM THE POOL <br /> 5 4'0" I 5 5.ALL INSIDE POOL DIMENSIONS ARE TO BE <br /> FINISHED DIMENSIONS. <br /> 8 � 8 6.FINISHED BOTTOM IS TO BE 2'MIN.OF <br /> H- SUITABLE MATERIAL OR UNDISTURBED EARTH. <br /> 7.A SAFETY LINE,WITH BUOYS,IS TO BE PER- <br /> $' 18'0" -i 8 SIDE OF THE DMANENTLY ANT OF FIRSTS OPE CHANGE. <br /> PA LIGHT ' CHED 1'0"TO THE SHALLOW <br /> 2 10'O" I I STEP 8.COPING:COPING LENGTHS ARE APPROXIMATE. <br /> PANEL I -+ UNIT FOR PROPER FIT.CUTS MAY BE RADIUS ADI S CORNERS AREDED ON STRAIGHT 2'x SECTIONS <br /> OPTION I <br /> 9.CONSTRUCTION DRAWINGS:THESE DRAWINGS <br /> AND NOTES ARE FOR ILLUSTRATIVE PURPOSES <br /> I� I 8 ONLY.DIFFERENT METHODS AND PRECAUTIONS <br /> 8 � MAY BE DICTATED BY VARIOUS GROUND CONDI• <br /> 5 4�0 I 5 TIONS.THIS IS TO BE DETERMINED BY AND IS <br /> THE RESPONSIBILITY OF THE CONTRACTOR, <br /> I WHO IS NOT AN AGENT OF THE MANUFACTURER <br /> 1 - OF THE ROYAL POOL <br /> 10.INSTALLATION IS TO BE DONE IN ACCORDANCE <br /> 4 i 8 1 8 1 8 8 WITH ALL FEDERAL STATE,AND LOCAL <br /> 12 12 8 BUILDING CODES,AS WELL AS N.S.P.I.SUG- <br /> F. GESTEDI STANDARDS. <br /> T , <br /> 8 4-RADIUS CORNERS $ NSPI DIVING POOL <br /> 4 REFER TO CURRENT N.S.P.I.PUBLICATIONS <br /> 3 4° _ 5 -12 SECTIONS TO DETERMINE TYPE&LOCATION OF <br /> D4 8�SECTIONS _ FORIVING MOREENFORMATIONUIPMENT LCCONSULT <br /> 6 6 NATIONAL SPA&POOL INSTITUTE <br /> 7 10° — 2111 AVENUE <br /> 2�� MINIMUM ALEXANDRIA EISENHOWERR VEE <br /> - PREPARED BOTTOM <br /> 12 I 12 j 8 f TEL DR 838-0083 ,. <br /> 2314 <br /> .,ti, COPING LAYOUT TITLE <br /> 18 x 36 RECTANGLE ` <br /> • H4,0„+{`- 6'0° f- 13'6” .L. 12'6° .• DATE SCALE DRAWN BY W.C.C. <br /> 1/1 /86 NONE APPROVED BY • <br />