My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Septic System Inspections
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
0365 Willow Drive North - 33-118-23-41-0012 State of MN/MN Dot
>
Permits/Inspections
>
Septic System Inspections
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:51:19 PM
Creation date
2/11/2020 1:26:51 PM
Metadata
Fields
Template:
x Address Old
House Number
365
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
365 Willow Drive North
Document Type
Permits/Inspections
PIN
3311823410012
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF ORONO O <br /> Municipal Offices O Atom\ <br /> Post Office Box 66 -_ <br /> VAP <br /> Crystal Bay, MN 55323-0066a r ON—SITE SEWAGE TREATMENT <br /> t. <br /> , 4f). INSPECTION REPORT <br /> 4 <br /> k�sKo <br /> Owner: 68Yn9(rdAddress: S Pi 4110)A) b ii-14 <br /> Permit #'s: Si)/r30 Dates:S—P-/-KVQ-g}-$ Contractors: ET 1,q3ca{YS/ <br /> City ordinance number 100 requires that each on-site sewage treatment system in Orono be inspected on a regular basis. <br /> The on-site sewage treatment system at the above address has been inspected and appears to fall into the category <br /> checked below. `/ <br /> (This is fX] an existing system [ ] new construction) <br /> SYSTEM CONFORMITY (1-3): <br /> 1 "CODE SYSTEM"-A system which meets all the location, design, and construction standards of the current City <br /> Codes, and which is operating satisfactorily by treating and disposing of the entire current sewage input <br /> without discharging any pollutants into ground or surface waters. <br /> 2 "CONFORMING SYSTEM"-A system which does not meet all the location, design, and construction standards of the <br /> current City Codes, but was installed according to the code in effect at the time of installation, and which <br /> is operating satisfactorily by treating and disposing of the entire current sewage input without discharging <br /> any pollutants into ground or surface waters. <br /> 3 "NON-CONFORMING SYSTEM"-A prohibited system; a system located within a designated 100-year floodplain; any <br /> system which may or may not meet all the location, design, and construction standards of the current City <br /> Codes and which is failing for any reason; and any system with less than 3 feet of unsaturated soil or sand <br /> between the distribution device and the limiting soil characteristics. <br /> (The limiting soil characteristic 1[ has or [ ] has not been identified at this time. If the limiting soil <br /> characteristic has not been identified, this classification may be subject to revision.) <br /> TANK CONDITION (5-10): -6 <br /> Tank inspection indicates: <br /> Pumpout not needed at this time. <br /> C-: <br /> Solids accumulation in tanks indicates .e should be • •-d out this year to help prevent u u.- - - <br /> Solids accumulation in tanks is at a critica -- - - - --- . - •., -s ••ssib - <br /> 8 System is discharging to the surface. Tanks must be pumped out within 48 hours to eliminate surface discharge. <br /> 9 Inspection risers missing-tanks could not be inspected. Inspection risers (4" dia. pipe) must be installed in each <br /> tank at next pumpout. If tanks have not been pumped out within the last three years, they should be pumped <br /> out now. <br /> 10 Inspection pipe is located directly over tank baffle (does not give accurate measurement of solids accumulation). <br /> If tanks have not been pumped out within the last three years, they should be pumped out now. <br /> DRAINFIELD CONDITION (11-14): .1..! <br /> Dr field inspection indicates: <br /> ] Drainfield is dry, no surfacing evident. <br /> 12 Some evidence of surfacing, not critical yet. <br /> 13 Drainfield is saturated and visibly discharging untreated effluent to the surface. Contact the City Inspector <br /> immediately. Repairs must be completed within 90 days. <br /> 14 Drainfield extent and condition unknown. <br /> LIMITING SITE FACTORS (slope,setbacks,etc.): <br /> POTENTIAL FOR SYSTEM FAILURE (depends on soils,water table,etc.): Zak_ <br /> COMMENTS: <br /> Da a of Inspection Sep , c Sys em Inspector <br /> Note: In the event that this inspection report is used to satisfy the requirements for a mortgage or other transfer of <br /> property, be advised that this report does not guarantee or certify that an existing system will continue to function <br /> properly, but is merely an opinion of the adequacy of the system under current conditions based on the available <br /> information. <br /> This report must be kept on the premises with the system location and pumping records. <br /> WHITE COPY/Inspectors File YELLOW COPY/Homeowner <br />
The URL can be used to link to this page
Your browser does not support the video tag.