• <br /> MINNESOTA DEPARTMENT OF HEALTH • tA <br /> 0 .j Pa <br /> Division of Environmental Health <br /> • REPORT ON PLANS . ' ' <br /> Plans and specifications on plumbing: Long Lake Fire Station, 340 Willow Drive, Long Lake,,, <br /> Hennepin County, Minnesota, Plan No. 022469 <br /> OWNERSHIP: City of Long Lake, do Mr. Joe Lynch, Clerk, Long Lake City Hall,P.O. Box 606, Long Lake, <br /> Minnesota 55356 <br /> SUBMITTER(S): Boatman Kroos Vogel Group, Inc., 222 North Second Street,Minneapolis,Minnesota 55401 <br /> Mid-City Mechanical Corporation, do Mr. Jim Poser, 9103 Davenport Street Northeast, <br /> Blaine, Minnesota 55449 <br /> Plans Dated: June 3, 2002 <br /> Date Received: June 4, 2002,April 30, 2002, March 18, 2002 <br /> Date Reviewed: June 4, 2002 <br /> SCOPE: This review is limited to the design of this particular project only insofar as the provisions of the <br /> Minnesota Plumbing Code, as amended, apply, and does not cover the water supply or sewerage system to whic <br /> this plumbing system is connected. The review is based upon the supposition that the data on whichthe design Is <br /> based are correct, and that necessary Iegal authority has been obtained to construct the project The ' <br /> responsibility for the design of structural features and the efficiency of equipment must be taken'by'de project <br /> designer. Approval is contingent upon satisfactory disposition of any requirements included in this report <br /> Special care should be taken to insure that the material and installation of the plumbing'system are in accordanc <br /> with the provisions of the Minnesota Plumbing,Code. .A copy•of.the approved plans and specifications:skioul <br /> be retained at the project location for future reference. <br /> INSPECTIONS: All plumbing installations must be tested and inspected in accordance with the requirements o <br /> the Minnesota Plumbing Code. As specified in Minnesota Rules, part 4715.2830,no plumbing work may be <br /> covered prior to completing the required tests and inspections_ Provisions must be made for applying an air test <br /> at the time of the roughing-in inspection as outlined in Minnesota Rules,part 4715.2820, subpart 2, of the code. <br /> A manometer test, as specified in Minnesota Rules, part 4715.2820, subpart 3, is required at the time of the <br /> finished plumbing inspection. It is the responsibility of the contractor/installer to notify the Minnesota <br /> Department of Health when an installation for a state contract job, licensed facility, or project in an area where <br /> there is no local administrative authority is ready for an inspection and test. To schedule inspections, contact th; <br /> state plumbing standards representative for your region, or call the metro office inspection hotline at 1-800-926- <br /> 6216 (7:30 ani to 9 a_rn.), or 651/215-0836 (8 a.m. to 9 a.m.) on Monday,Wednesday or Friday. <br /> • <br /> REQUIREMENT(S): <br /> 1. Double wyes may not be used for drainage fittings in the horizontal position (see Minnesota Rules. <br /> part 4715.2420, subpart 3). Proper pipe slope cannot be maintained on both of the offset branches. The <br /> trench drains in the garage area and the floor drain in Room No. 115 appear to be served with double wyes <br /> in the horizontal position. <br /> 2: The installation of reduced pressurezone backflow preventers is permitted-only when periodic testing.is <br /> done by a trained bacl'low preventer tester acceptable to the•administrative authority: Testing intervals • <br /> shall not exceed one year, and.records must be kept All;devices•must be tested'after initial installation to <br /> assure that debris from the piping installation has not interfered with the functioning of the device: The - <br /> devices shall be overhauledat least once every five years. The installation of new backflow preventers nn ,t <br /> be at least 12 inches, but not more than 6 feet above the•finished floor or ground level. This is in referenc <br /> to the RPZ connections to the irrigation and pressure washer systems. <br /> £00/ZOO'd 6bL9# 2 'dI Ou07 30 ALIO ZZ96 9L17 Z56 Zi7:TT ZOOZ,9T'Inr <br />