Laserfiche WebLink
Farm for Inspection,Testing and Maintenance of Fire Pumps --- <br /> (0 <br /> Information on this form covers the minimum requirements of NFPA 25-1995 for centrifugal fie pumps. Separate forms wssoorw� <br /> are available to inspect,test and maintain the rest of the fire protection system of which the fire pump is a part More <br /> frequent inspection,testing and maintenance may be necessary depending on the conditions of the occupancy and water supply. <br /> PP Y• <br /> Owner: �/VO S p SC-A/00L <br /> Owner's Address: e z <br /> Property Being Inspected: <br /> Property Address: <br /> Date of Inspection: _t9 <br /> This inspection is(check one) O Weekly O Monthly O Quarterly O Semiannual Ak Annual <br /> Note: All questions are to be answered Yes,No or Not Applicable. All"No"answers are to be explained in the comments portion of this form. <br /> All responses refer to the current inspection performed on the date shown above. <br /> ' B. Tests <br /> Bre �yRrasp:' 1. Weekly Test Items <br /> j <br /> A. Electric Motor-driven Pumps <br /> 011 e 1. Pump started automatically? _715- O p&Yes O No N/A <br /> j• IF.W M .• '. <br /> oeitaiTarntri, Record starting pressure."•' trv��.�-.� .., •a.ti R'.;..;, sure. Psi. <br /> r+ ` 2. Pump rut for at least 10 minutes?. <br /> Yes O No O N/A <br /> tee <br /> tv�i/t P Record suctionl and discharge�G pressure while naming. <br /> <, 3. Pump Packing gland showing slight discharge? <br /> or svpenarttetiva t t�atne � <br /> Adjust if necessary. <br /> Ayes O No O N/A <br /> '^ <br /> Seettola � C1,r�•r�nf . s6q• 4. Free from unusual noises or vibrations? Yes No O N/A <br /> � ns actor s '� "r' < ?l t., _ 5. Packing boxes,bearings and pump casing free from overheating? <br /> A. Inspections-All to be performed weekly. AC-Yes O No O N/A <br /> 1. Pump houseroom at least 40"F? 49 Yes O No ❑ N/A 6. Record time for motor to accelerate to full speed, l 3 <br /> 2. Pump house/room for diesels without engine heaters at least 70°F? 7. For reduced voltage or reduced current starting.record time <br /> 0 Yes 0 Noe$N/A controller is on first step. <br /> 3. Ventilating louvers free to operate? ❑ Yes O No 4K.N/A 8. For automatic stop controllers,record time pump nuns after <br /> 4. Suction,discharge and bypass valves open? WrYes O No O'N/A starting. ' ^-%%A! <br /> 5. Piping free from leaks? W Yes 0 No O N/A 9.All times and pressures in Part A acceptable?A Yes❑No❑ N/A <br /> 6. Suction and system pressure gauges normal? Yes O No O N/A B. Diesel Engine-Driven Pumps <br /> 7. Suction reservoir,if provided,full? fiT-Yes 0 No O N/A I- Pump started automatically? ❑ Yes O Nos N/A <br /> 8. Controller indicating power on? V Y'Yes ❑ No ❑ N/A Record starting pressure. psi. <br /> 9. Transfer switch indicating normal situation? V*%s ❑ No 0 N/A 2, Pump run for at least 30 minutes? (3 Yes O NajWN/A <br /> 10. Isolation switch closed? C'Yes O No O N/A <br /> 11. Reverse phase alarm indicator off or Record suction and discharge pressure whileHoming. <br /> normal phase rotation indicator on? 90 Yes O No 0 N/A 3• Pump Peng gland showing slight discharge?0 Yes O No I N/A <br /> 12. Oil level in vertical motor sight normal? ❑ Yes 0 NoP4 N/A Adjust if necessary- <br /> 13. Diesel Engine Inspection 4. Free from unusual noises or vibrations? 0 Yes 0 No4N/A <br /> a. Fuel tank at least two thirds full? O Yes O Nog N/A S. Packing boxes,bearings and pump casing free from overheating <br /> b. Controller selector switch in Auto position?O Yes O NoCk N/A 0 Yes O Nod1Z4/A <br /> c. Battery voltage and readings normal? O Yes O No A!f-N/A 6• Record time for engine to crank. <br /> d. Battery charging current readings normal? O Yes O No ffN/A 7• Record time for engine to reach running ring speed• <br /> e. Battery indicators on or failure indicators off?0 Yes O Noa&N/A 8. Engine oil pressure gauge,speed indicator,water and oil <br /> f. All alarm indicators off? O Yes O No$"/A temperature indicators all reading normal? O Yes O No,Q N/A <br /> 9. Cooling water flowing from heat exchanger? O Yes 0 No p,: A <br /> g. Record engine running time meter reading. Is this 10.All times and pressures in Part B acceptable?O Yes 0 No AK'N/A <br /> appropriately higher than previous reading?O Yes O No l0.N/A C. Steam Turbine-driven Pumps <br /> h. Oil level in right angle gear drive normal? O Yes O NoJ05,N/A 1• Record pump starting pressure ,strction and <br /> i. Crankcase oil level normal? O Yes ❑ No 0"V/A <br /> j. Cooling water level normal? O Yes ❑ No OLN/A discharge pressures while naming. <br /> k. Electrolyte level in batteries normal? O Yes O No dJKN/A 3. Pump packing gland showing slight discharge?O Yes 0 No 91�N/A <br /> 1, Battery terminals free from corrosion? O Yes O NoO/A Adjust if necessary. <br /> m. Water jacket heater operong? 0 Yes 0 No N/A 4. Free from unusual noises or vibrations? O Yes 0 No 44 N/A <br /> 14. Steam pressure gauge for steam driven pump reading normal? 5. Packing boxes,bearings and pump casing free from overheating) <br /> O Yes 0 No'dN/A O Yes O No^\N/A <br /> 15. Circulation relief valve flowing water while pump chums? 6. Record steamressure <br /> P Barge reading. <br /> jd Yes 0 No O N/A 7. Record time for turbine to reach naming speed. <br /> 16. Pressure relief valves operating with proper pressure downstream 8. All times and pressures in Part C acceptable?O Yes O No 4T N/A <br /> while pump is operational? 4:8,Yes 0 No O N/A <br /> 01994 National Fire Sprinkler Association, P.O. Box 1000,Patterson,NY 12563(914)878-4200 Used by permission. Form 25-20 Sheet I oft <br />