aPEAATIUN ❑PNEUMATIC .IzAhf--THIL; URTuevwu%. <br /> P1PING SUPERVISED Q YES C N O DETECTING MEDIA SUPERVISED O YES Q NO <br /> DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS Q YES Q NO <br /> DELUDE A IS THERE AN ACCESSIBLE FAC:UTY IN EACH C:ACUIT FOR TESTING IF NO,EXPLAIN <br /> PREACriON <br /> VALVES Q YES QNO <br /> DOES EACH CIRCUIT OPERATE DOES EACH C:RCUIT MAXIMUM TIME 70 <br /> MAKE I MODEL SUPERVISION LOSS ALARM OPERATE VALVE RELEASE OPERATEf YES No Y155 I NO MIN. <br /> AELE/�SE <br /> HYDROSTATIC.Hydrostatic tests snali be made at not lees then 200 tlsl(136 bars)for two hours or 50 par(3A barsl above static prserim in encase <br /> of 150 psi(10.2 bans for two hours Oifferential dry-pipe valor c=pers snag be cert open dunnq test to prevent damage,All aboveground piping <br /> TEST leakage snad be swoped. <br /> 0E21CRI1111PTION PNEUMATIC:Establisn e,0 psi(2.7 bars)air pressure and measure droo which shad not eeaed 1+A psi(0.1 bars)In 24 hours.Test pressure tanks at <br /> normal water,ever and air pressure and measure air pressure droo which snag not each'1'A psi(e,1 bars►in 24 hours. <br /> ALL PIPING HYDROSTATICALLY TESTED AT PSI FOR HAS. IF NO,STATE REASON <br /> DRY PIPING PNEUMATICALLY TESTED O YES Q NO <br /> EQUIPMENT OPERATES PROPERLY O YES CO NO <br /> DO YOU CERTIFY AS THE SP91NKLER CONTRACDR THAT ADDITIVES AND CORROSIVE CHEMICALS.SODIUM SILICATE OR DERIVATIVES <br /> _Of SODIUM SILICATE BRINE.OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? <br /> 14171 <br /> TESTS DRAINI READING OF GAGE LOCATED NEAR WATER SUPPLY TEST PIPE. RESIDUALPAESSURE WITH VALVE IN TEST PIPE OPEN WIDE <br /> TEST 1 STATIC PRESSURE PSI PSI <br /> Underground mains and lead in connections to system risers flushed before connection made to sprinider piping. <br /> VERIFIED BY COPT CF THE U FORM NQ 858 Q YES O NO EXPLAIN <br /> FLUSHED 8Y INSTALLER OF UNDER- <br /> GROUND SPRINKLER PIPING O YES O NO <br /> YI(TE-7NG NUMBER USED I LCC.ZTIONS NUMBER REMOVED <br /> %Sr 414 <br /> WELDED PIPING YES C NO <br /> IF YES... <br /> 00 YOU CERTIFY AS THE SPRINKLER CONTRACDR THAT WELDING PROCEDURES COMPLY <br /> WITH THE REQUIREMENTS OF AT LEAST AWS 0105.L—=IELAR3 PtYES C NO <br /> WELDING DO YOU CERTIFY THAT THE WELDING WAS PERFORMED 13Y WELDERS QUALIFIED IN <br /> COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS 0109.LEVEL AR-3 111t1YES O NO <br /> DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN CCMPUANCE WITH A <br /> DOCUMENTED QUALITY CONTRCL PROCEDURE i'0 INSURE THAT ALL DISCS ARE <br /> RETRIEVED.THAT OPENINGS IN PIPING ARE SMOOTH.THAT SLAG AND OTHER <br /> WELDING RESIDUE ARE 9EMCVEM AND THATTHE INTERNAL DIAMETERS OF <br /> PIPING ARE NOT PENETRATED YES C NO <br /> CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL <br /> (DISKS) CUTOUTS(DISKS)ARE RETRIEVED AYES Q NO <br /> HYDRAUUC NAMEPLATE PROVIDED ( IF NQ EXPLAIN <br /> NAMEPLATE O YES •O NO <br /> GATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: <br /> //1/6 9 <br /> REMARICS <br /> NAME OF SPRINKLER CONTRACTOR <br /> TESTS WITNESSED 9Y <br /> SIGN=RE8 FOR P PC. OWNER(SIGNED) DATE <br /> I7Vt(C.Qt 0r CX . -16 .5 <br /> FORIP6IINKLER CON (SIGNED) ��T3� DATE <br /> ADDITIONAL EXPLANATION AND NOTES <br /> 85A BACK <br />