My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2017 - 00589 - siding
Orono
>
Property Files
>
Street Address
>
W
>
Willow Drive North
>
0041 Willow Drive North - 33-118-23-44-0031
>
Permits/Inspections
>
2017 - 00589 - siding
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 4:52:51 PM
Creation date
2/10/2020 1:18:46 PM
Metadata
Fields
Template:
x Address Old
House Number
41
Street Name
Willow
Street Type
Drive
Street Direction
North
Address
41 Willow Drive North
Document Type
Permits/Inspections
PIN
3311823440031
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Technical Evaluation Report(TER) <br /> Stud Spacing and Cladding Weight when Connected to Wood Studs Using HeadLOK Fasteners6,7 <br /> 5.3.2. Check for wind resistance. <br /> Step 1: Using the information derived from Steps 1-5 in Section 5.3, determine the allowable design wind <br /> pressure using HeadLOK fasteners from Table 3 below. <br /> Allowable Design Wind Pressure <br /> Furring or WSP Installation Condition Min. 1x4 Wood Furring Min. 1x4 Wood Furring Min.3/8"WSP and Min.3/e"WSP and <br /> at 16"o.c. at 24"o.c. 16"o.c.studs 24"o.c.studs <br /> HeadLOK Fastener Spacing in Furring 24 16 12 8 24 16 12 8 12 8 6 12 8 6 <br /> or Sheathing(in) <br /> Connection Allowable Design Wind 49 73 98 147 33 49 65 98 49 73 98 33 49 65 <br /> Pressure(PSF) <br /> 1) Wood framing and furring shall be minimum Spruce-Pine-Fir or any species with specific gravity,G,of 0.42 or greater. <br /> 2) Connection allowable design wind pressure applies to connection resistance only and shall meet or exceed design wind pressure. <br /> 3)Wood framing,furring,and sheathing shall be of adequate size,species,and grade to resist design loads and requirements in accordance with the applicable building code. <br /> 4)Where required by applicable building code,adequate resistance of connections and materials to seismic forces shall be provided based on local seismic ground motion <br /> hazard and the weight of the supported cladding system. <br /> Table 3:Allowable Design Wind Pressure for Connections Using HeadLOK Fasteners <br /> Step 2: Based on the design wind speed (85-140mph)and wind exposure category(A-D)specific to your <br /> region, determine the design wind pressure to be resisted for your application from Table 4 <br /> below. <br /> Example Design Wind Loads <br /> Design Wind Speed(mph)&Exposure 85/B 90/B 100/B 110/B 120/B 130/B 140/B <br /> 5'e - - 85/C 90/C 100/C 110/C 120/C <br /> - - 85/D 90/0 100/D 110/D <br /> Design Negative Wind Pressure Load to be Resisted(psf) 17.4 19.5 24.4 29.1 34.7 40.7 48.3 <br /> 1)Mean roof height shall not exceed 30'(measured vertically from grade plane to middle of roof slope). <br /> 2)Refer to applicable building code for wind exposure descriptions(B=typical suburban/wooded terrain;C=open flat terrain;D=ocean/lake exposure). <br /> 3)Where topographic effects occur(e.g.,wind speed up due to hill-top exposure),refer to building code for wind load. <br /> 4)Tabulated wind pressures are from ASCE 7-05,for wall corner zones.For lesser values away from wall corners,refer to the building code. <br /> 5)Tabulated wind pressures assume 100%of wind load is resisted by the cladding/foam sheathing or furring/foam sheathing layer and not otherwise distributed or shared with <br /> other wall assembly layers. <br /> Table 4:Example of Components and Cladding Design Wind Loads <br /> Step 3: Verify that the allowable design wind pressure using HeadLOK fasteners(Table 3) meets or <br /> exceeds the design wind pressure for your project(Table 4). <br /> 5.3.3. Design Example: <br /> Given <br /> Foam Sheathing Thickness: 4" <br /> Cladding Material: Fiber cement lap siding <br /> Cladding Weight from Manufacturer Data: 3 psf <br /> Design Wind Speed/Exposure: 100/B <br /> Seismic Design Category: B (exempt) <br /> Wood Framing: 2x6 at 24" o.c. <br /> 6 For cladding system weights exceeding 25 psf with any thickness of foam sheathing,a design professional should be consulted. <br /> 7 Table 2 solutions are limited to 4"maximum thickness of foam sheathing.Design required for thicknesses of foam sheathing greater than 4".For cladding attachment over foam <br /> sheathing exceeding a 4"thickness,a design professional should be consulted. <br /> TER No. 1009-01 Page 5 of 12 <br /> Use of FastenMaster HeadLOKTM Fasteners to Attach Cladding <br /> and/or Furring to Wood Framing through Foam Sheathing <br />
The URL can be used to link to this page
Your browser does not support the video tag.