Laserfiche WebLink
4 Load Short Form Job: <br /> WtIgI7tS0 a Date: <br /> Entire House By: • <br /> Genz-Ryan Plumbing and Heating <br /> 2200 W Highway 13,Burnsville,MN 55337 Phone:952-767-1000 Fax:952-767-1900 Email:info@genzryan.com Web:genxiyan.com <br /> Project Information <br /> For: Highmark-Kahlert-Hanson <br /> Design Information <br /> Htg Clg Infiltration <br /> Outside db (°F) -15 88 Method Simplified <br /> Inside db(°F) 72 75 Construction quality Semi-tight <br /> Design TD (°F) 87 13 Fireplaces 1 (Average) <br /> Daily range - M <br /> Inside humidity(%) 30 50 <br /> Moisture difference(gr/lb) 58 35 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Make <br /> Trade Trade <br /> Model Cond <br /> AHRI ref Coil <br /> AHRI ref <br /> Efficiency 96AFUE Efficiency 11.6 EER, 14 SEER <br /> Heating input 0 Btuh Sensible cooling 0 Btuh <br /> Heating output 0 Btuh Latent cooling 0 Btuh <br /> Temperature rise 0 °F Total cooling 0 Btuh <br /> Actual air flow 1740 cfm Actual air flow 1740 cfm <br /> Air flow factor 0,023 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.89 <br /> ROOM NAME Area Htg load Clg load HtgAVF CIgAVF <br /> (ft2) (Btuh) (Btuh) (cfm) (cfm) <br /> Room2 2059 38648 20403 874 956 <br /> Room4 1924 22913 11019 518 516 <br /> Room5 1014 15422 5724 349 268 <br /> Entire House 4997 76983 37147 1740 1740 <br /> Other equip loads 13079 654 <br /> Equip. @ 0.93 RSM 35117 <br /> Latent cooling 4519 <br /> TOTALS 4997 90063 39636 1740 1740 <br /> Bold4talic values have been manually overridden <br /> Calculations approved byACCA to meet all requirements of Manual J 8th Ed. <br /> wrightsoft Right-Suite®Universal 2017 17.0.04 RSU14477 2017-Sep-01 13:36:40 <br /> Pagel <br /> AZ—CA ..ACTS1AFWRIGHTSOFPH1ghmark Kahleri Hanson.rup CaIc=MJ8 Front Door faces:N <br />