Laserfiche WebLink
t RECEIVED <br /> ' New Construction Energy Code Compliance Certificate SEP 1 1 1017 <br /> Per R401.3 Certificate.A building certificate shall be posted on or in the electrical distribution panel- Date Certificate Posted <br /> COPY OF THIS DOCCUMENT WILL HE POSTED ON THE PLENTUM OF FURNACE ;TN(� Q5ONO <br /> Mailing Address of the Dwelling or Dwelling Unit: City: J�C�rC1u1 <br /> 17— tat iVS4 1-Jµ`1 logo here <br /> Name of Residential Contractor: MN}i,c,ense Number <br /> 41‘4.-6,..,k ' IAAct v . f vtc i. 7C-146 0 sy <br /> 'THERMAL ENVELOPE RADON CONTROL SYSTEM <br /> Type:Check All That Apply X Passive(No Fan) <br /> Active(With fart and monometer <br /> CUPY <br /> or other system monitoring <br /> device) <br /> m y Location(or future location)of Fan: <br /> W— b a o IF fan is required:Attic <br /> I u c a ' Q <br /> o 'lig z U a) o -a m <br /> =T. Q m m N C lc-, r.,' <br /> > C O IN6 2 U - � _2 • <br /> Insulation Location z O <br /> • Ua `o 6 ) E g awi v 32 <br /> o o O P -0 o oO C m " <br /> H 5 z i1 i t I E E Other Please Describe Here <br /> Below Entire Slab X <br /> Foundation Wall R-15 X R402.2.8,Exception;a.R-10-by plan <br /> Perimeter of Slab on Grade X _ <br /> Rim Joist(1st Floor) R-20 X <br /> Rim Joist(2nd Floor+) R-20 x _ <br /> Wall R-21 X <br /> Ceiling,flat R-49 X <br /> Ceiling,vaulted R-49 X _ <br /> Bay Windows or cantilevered areas R-30 x <br /> Floors over unconditioned area R-30 X_ <br /> Describe other insulated areas <br /> Building envelope air tightness: Duct system air tightness: <br /> Windows 8 Doors Heating or Cooling Ducts Outside Conditioned Spaces <br /> Average U-Factor(excludes skylights and one door)U: 0.32 Not applicable,all ducts located in conditioned space <br /> Solar Heat Gain Coefficient(SHGC): 0.34 8 R-value <br /> MECHANICAL SYSTEMS Make-up Air Select a Type <br /> Domestic Water <br /> Appliances Heating System Heater Cooling System X Not required per mech.code <br /> Fuel Type Natural Gas Natural Gas Electric Passive <br /> Manufacturer Carrier RHEEM Carrier Powered <br /> Interlocked with exhaust device. <br /> Model ML193 PROG75 24ACC Describe: <br /> Input in 10000 Capacity in 75 Ouipul 4 Other,describe: <br /> Rating or Size BTUS: Galons: in Tons: <br /> AFUE or 96 SEER 15 Location of duct or system: <br /> Efficiency HSPF% JEER <br /> Residential Load Heating Loss Heating Gain Cooling Load <br /> Calculation 90063 44400 Cfm's <br /> "round duct OR <br /> MECHANICAL VENTILATION SYSTEM "metal duct <br /> (Describe any additional or combined heating or cooling systems if installed:(e.g.two furnaces or air Combustion Air Select a Type <br /> source heat pump with gas back-up furnace): i <br /> Not required per mech.code <br /> Select Type X Passive <br /> Heat Recover Ventilator(HRV) Capacity in cfms: Low: _High: Other,describe: <br /> X Energy Recover Ventilator(ERV)Capacity in cfrns: _Low: 97 High: 194 Location of duct or system: <br /> X Balanced Ventilation capacity in cfms: Mechanical al Room <br /> Location of fan(s),describe: Cfm's <br /> Capacity continuous ventilation rate in cfms: 6" "round duct OR <br /> Total ventilation(intermittent+continuous)rate in cfms: "metal duct <br /> Builders Association of Minnesota version 101014 <br />