2001 Geotechnical Evaluation Report
Orono
>
Property Files
>
Street Address
>
W
>
Wildhurst Trail
>
1080 Wildhurst Trail - 07-117-23-24-0011
>
Land Use
>
2001 Geotechnical Evaluation Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 5:32:51 PM
Creation date
2/6/2020 1:29:24 PM
Metadata
Fields
Template:
x Address Old
House Number
1080
Street Name
Wildhurst
Street Type
Trail
Address
1080 Wildhurst Tr
Document Type
Land Use
PIN
0711723240011
Supplemental fields
ProcessedPID
Updated
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RVC Homes <br /> Project BABX-01-0124 <br /> April 12, 2001 <br /> Page 5 • <br /> C.4. Pile Foundations <br /> We have reviewed several pipe pile sizes that are commonly used to provide the recommended pile <br /> capacities in soil conditions similar to this project. Other suitable pile types may also be available and <br /> pile-driving contractors often offer alternate pile as part of their bid. If an alternate pile type is <br /> proposed, we would be pleased to provide our analysis and opinion as to the suitability of the alternate <br /> pile for the project. We chose two commonly used pipe sizes for our analysis,they are 12 3-4-inch OD <br /> and 9 5/8-inch OD pipe. These pile sizes also correspond to those offered by Atlas Foundation <br /> Company. <br /> C.4.a. Allowable Positive Geotechnical Capacities. Allowable positive geotechnical pile capacities <br /> are determined by dividing the ultimate positive geotechnical pile capacities by a factor of safety. The <br /> American Association of State Highway and Transportation Officials (AASHTO) recommend the <br /> safety factor be related to the degree of construction control. A listing of the factors of safety is <br /> provided in Table 1. <br /> Table 1. Recommended Factors of Safety <br /> Specified Construction Control Factor of Safety <br /> Dynamic formula 3.50 <br /> Wave equation(computer analysis with hammer and driving data) • 2.75 <br /> Wave equation and Pile Dynamic Analyzer(PDA) 2.25 <br /> Static load test and dynamic formula, wave equation and/or PDA 2.00 <br /> Wave equation. PDA and static load test 1.90 <br /> Based on Table 4.5.6.2A of AASHTO's Standard Specifications for Highway Bridges, 1996 <br /> C.4.b. Ultimate Positive Geotechnical Capacities. We used a combination of methods including <br /> DRIVEN to predict the ultimate positive geotechnical vertical static capacities of piles. DRIVEN is a <br /> computer program developed for the Federal Highway Administration. <br /> We assumed the pile cut-off elevations will be approximately 4 feet below the lowest level slab <br /> elevation; i.e., we assumed the cutoff elevations will be about 929. We also assume a static pile load <br /> test would not be economically feasible for a project of this size, therefore pile lengths given assume the <br /> AASHTO recommended safety factor would be 2.25 when using the wave equation analysis and <br /> dynamic pile testing to judge pile capacity. <br />